Ferrocene anchored fluorescent cellulose nanofibers for ultrasensitive detection, adsorption, and Fenton degradation of norfloxacin: VOSviewer analysis, performance, mechanism, & RSM optimization.
Kavita Sharma, Sumit, Shubham Sharma, Gaurav Rattan, Anupama Kaushik
Energy Research Centre, Panjab University, Chandigarh, India; Lloyd Institute of Engineering and Technology, Greater Noida, India. · Energy Research Centre, Panjab University, Chandigarh, India.
Key points
From the paper's conclusion- Hence, this study has addressed this aforementioned shortcoming by critically synthesizing and comprehensively characterizing a novel fluorescent sensor, FcCA@ACNFs, formed via covalent Schiff base bonding between the Ferrocene carboxaldehyde (FcCA) and aminated cellulose nanofibers (ACNFs).
Abstract
As revealed by in-depth state-of-the-art literature analysis using VOSviewer, no study to date has been specifically reported on the Ferrocene carboxaldehyde anchored on the aminated cellulose nanofibers (FcCA@ACNFs) multifunctional hybrid fluorescent sensor, especially for comprehensive wastewater remediation encompassing trace-level detection, efficient adsorption, and Fenton-based degradation of Norfloxacin (NOR) antibiotic from wastewater. Hence, this study has addressed this aforementioned shortcoming by critically synthesizing and comprehensively characterizing a novel fluorescent sensor, FcCA@ACNFs, formed via covalent Schiff base bonding between the Ferrocene carboxaldehyde (FcCA) and aminated cellulose nanofibers (ACNFs). The fluorescence was significantly enhanced in the presence of NOR, exhibiting a high turn-on selectivity with LOD of 0.97 nM in the linear range of 1-100 mg L-1. The average fluorescence lifetime, ⟨τ⟩, estimated using time-resolved fluorescence lifetime spectroscopy, was 3.4905 ns for a higher concentration of NOR in the FcCA@ACNFs-NOR complex, indicating a near-high analyte concentration. Additionally, the statistical tool, Response Surface Methodology (RSM) using Box-Behnken Design (BBD) was used to determine the effect of pH, time, NOR concentration, and FcCA@ACNFs dosage on % adsorption. Adsorption kinetics were described using a pseudo-second-order kinetic model, yielding a maximum Langmuir adsorption capacity of 416.66 mg g-1 and R2 of 0.9992. Concomitantly, FcCA@ACNFs completely degraded NOR in the presence of co-oxidant H2O2, as evident from LCMS studies. Fenton-based degradation followed first-order kinetics had a rate constant of 0.1767 min-1 and a t1/2 of 3.92 min. Under the optimized conditions, 69.87% mineralization of NOR was achieved within 60 min, as confirmed by TOC analysis, indicating substantial mineralization of NOR and its degradation intermediates. FcCA@ACNFs exhibited an excellent removal rate of 94.6% even after 10 cycles. Finally, the efficacy of multifunctional FcCA@ACNFs was established for real water-sample analysis, validating their potential as a promising material for ultra-sensitive detection and comprehensive removal of NOR from wastewater.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Hybrid Zr-MOF/CNT/Nanocellulose Electrochemical Sensor for Dual Detection of Furazolidone and Chloramphenicol in Food SamplesACS Applied Nano Materials · 2025
- Lanthanide metal–organic Framework Fluorescent Sensor for the Detection of Furazolidone in Tap Water and Animal FeedInorganic Chemistry · 2026
- Ferrocene-functionalized NH2-UiO-66/MoO3 ratiometric electrochemical sensing platform for efficient monitoring of levofloxacin.Mikrochimica acta · 2026
- Development and optimization of a vortex-assisted micro-solid phase extraction (VA-µSPE) method for sensitive fluoxetine determination using a novel CoNiCr-LDH@ND-COOH nanocomposite.Analytical methods : advancing methods and applications · 2026
- Selective electrochemical determination of norfloxacin in food samples using template-derived recognition cavities and conductive nanostructured networks.Analytical and bioanalytical chemistry · 2026
- A highly sensitive fluorescent nickel-based coordination polymer for Nitrofuran antibiotics detection in real water samples.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026