Diagnostic accuracy of bicycle ergometry for ischemic heart disease using stress computed tomography myocardial perfusion imaging with vasodilator testing as the reference standard.

Basheer Abdullah Marzoog, Peter Chomakhidze, Philipp Kopylov

Institute of Personalized Cardiology of The Center "Digital Biodesign and Personalized Healthcare" of Biomedical Science and Technology Park, Sechenov First Moscow State Medical University, 119991 Moscow, Russia; postal address: Russia, Moscow, 8-2 Trubetskaya street, 119991. Electronic address: marzug@mail.ru. · Institute of Personalized Cardiology of The Center "Digital Biodesign and Personalized Healthcare" of Biomedical Science and Technology Park, Sechenov First Moscow State Medical University, 119991 Moscow, Russia; postal address: Russia, Moscow, 8-2 Trubetskaya street, 119991.

Key points

From the paper's conclusion
  • In this cohort, bicycle ergometry showed limited accuracy for detecting ATP stress CTP-defined myocardial perfusion defects; these findings should not be generalized to ischemic heart disease overall.

Abstract

BACKGROUND: Exercise bicycle ergometry remains widely available for suspected ischemic heart disease (IHD), but its accuracy against stress computed tomography myocardial perfusion (CTP) imaging is uncertain. OBJECTIVES: To evaluate the diagnostic accuracy of bicycle ergometry for detecting stress-induced myocardial perfusion defects on adenosine triphosphate stress CTP. METHODS: This prospective, single-center, observational diagnostic accuracy study included 80 adults aged ≥40 years with suspected IHD/chronic coronary syndrome, written informed consent, and protocol-defined pre-test probability of IHD between 1% and 33%. Participants with diabetes mellitus, recent acute coronary syndrome or myocardial infarction, acute inflammatory disease, major respiratory disease, contraindications to exercise testing, radiocontrast or adenosine triphosphate allergy, eGFR <30 mL/min/1.73 m², or other protocol-defined non-inclusion criteria were not enrolled. Recruitment was eligibility-based and was not documented as consecutive. Bicycle ergometry was the index test. Stress-induced myocardial perfusion defect on CTP was the reference standard. In the primary analysis, only clearly positive bicycle ergometry was classified as index-test positive; suspicious/equivocal and negative tests were classified as non-positive. A sensitivity analysis classified suspicious/equivocal tests as positive. RESULTS: Stress CTP showed perfusion defects in 31/80 participants. In the primary analysis, sensitivity was 12.90% (95% CI, 3.63-29.83%), specificity 73.47% (58.92-85.05%), LR+ 0.49 (0.17-1.36), LR- 1.19 (0.96-1.47), and accuracy 50.00% (38.60-61.40%). When suspicious/equivocal tests were classified as positive, sensitivity was 48.39% (30.15-66.94%), specificity 53.06% (38.27-67.47%), LR+ 1.03 (0.64-1.65), LR- 0.97 (0.63-1.50), and accuracy 51.25% (39.81-62.59%). CONCLUSION: In this cohort, bicycle ergometry showed limited accuracy for detecting ATP stress CTP-defined myocardial perfusion defects; these findings should not be generalized to ischemic heart disease overall.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Diagnostic accuracy of bicycle ergometry for ischemic heart disease using stress computed tomography myocardial perfusion imaging with vasodilator testing as the reference standard — Science Skim