Day-Night Patterns of Wearable-Derived Electrocardiographic Age and Left Atrial Remodeling in Atrial Fibrillation-Naïve Individuals.
Seung Hyun Park, Juhyun Jin, Jongwoo Kim, Dongha Lee, Daein Kim, Jaeseong Jang, Hee Tae Yu, Seng Chan You,
Yonsei University College of Medicine, Seoul, Republic of Korea. · Wellysis corp, Seoul, Republic of Korea.
Key points
From the paper's conclusion- Wearable-derived AI-ECG age exhibits a reproducible day-night pattern. A Disrupted phenotype is associated with adverse LA remodeling. Because reproducibility remains insufficient for individual-level classification, prospective outcome-based validation is warranted.
Abstract
BACKGROUND: Artificial intelligence-derived electrocardiographic (AI-ECG) age is conventionally treated as a static marker. Its diurnal dynamics and structural correlates in individuals without atrial fibrillation (AF) remain unknown. OBJECTIVE: To characterize diurnal AI-ECG age patterns, their reproducibility, and associations with left atrial (LA) remodeling. METHODS: We analyzed continuous wearable ECGs from two prospective registries (NCT05119725, NCT05355948). In 499 AF-naïve participants with ≥48-hour recordings, AI-ECG age was estimated every 10 minutes. Unsupervised clustering identified day-night trajectories, summarized by day-night difference (ΔAge) into Restorative (>0.6 years) or Disrupted (≤0.6 years) phenotypes. Reproducibility was evaluated across sequential periods. Age- and sex-adjusted associations of binary and continuous ΔAge with LA volume index (LAVI) were pooled in a cross-sectional echocardiographic substudy (n=122). RESULTS: Three trajectories emerged in both registries. Restorative prevalence was 47.6%-50.2%. Agreement between two consecutive 48-hour periods was 75.8% (κ = 0.516; 95% CI, 0.395-0.631); 6- to 8-day intraclass correlation coefficients were 0.51-0.54. The Disrupted phenotype was associated with higher LAVI (pooled mean difference, 5.54 mL/m2; 95% CI, 1.11-9.98; P = .014) and greater odds of LA enlargement (LAVI ≥40 mL/m2; pooled odds ratio, 3.68; 95% CI, 1.45-9.29; P = .006). Per 1-SD higher ΔAge, LAVI was lower (β, -2.89 mL/m2; P = .007) and LA enlargement less likely (odds ratio, 0.53; P = .004). CONCLUSION: Wearable-derived AI-ECG age exhibits a reproducible day-night pattern. A Disrupted phenotype is associated with adverse LA remodeling. Because reproducibility remains insufficient for individual-level classification, prospective outcome-based validation is warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Wearable device derived electrocardiographic age and its association with atrial fibrillationnpj Digital Medicine · 2026
- Explainable age prediction using a transformer trained on diverse global electrocardiograms.European heart journal. Digital health · 2026
- The AI-ECG clock as a biomarker of cardiovascular ageing: molecular, genetic and clinical validation in three cohortsEuropean Heart Journal · 2026
- Using an Artificial Intelligence ECG-Derived Biological Age for Risk Stratification of Patients Undergoing Surgical Aortic Valve Replacement.The Annals of thoracic surgery · 2026
- Artificial Intelligence-Enabled Electrocardiography Model for Left Ventricular Systolic and Diastolic Dysfunction Predict Incident Atrial Fibrillation in Patients with Sinus Rhythm: A Time-Dependent Analysis.Diagnostics (Basel, Switzerland) · 2026
- Artificial intelligence-derived ECG age and biological cardiovascular aging in competitive athletes: determinants independent of training exposureEuropean Heart Journal · 2026