Heart, lung & circulation

Suture-Only vs Hybrid Closure Techniques for Vascular Access Haemostasis in Percutaneous Cardiovascular Procedures: Systematic Review and Meta-Analysis.

Akshat Banga, Sidharth Misra, Sawai Singh Rathore, Ankit Agrawal, Sarju Ganatra, Jacqueline Latina, Stephen Gannon, Sourbha Dani

Department of Medicine, Mount Auburn Hospital, Harvard Medical School, Cambridge, MA, USA. · Department of Surgery, University of Texas Southwestern Medical Center, Dallas, TX, USA.

Meta-analysis

Key points

From the paper's conclusion
  • Use of the HSP technique for vascular access haemostasis after TAVR or pEVAR was associated with significantly lower rates of vascular complications, bleeding, and VCD failure compared with SO closure, without a significant difference in mortality.

Abstract

BACKGROUND: Vascular complications and bleeding increase morbidity and mortality after percutaneous cardiovascular procedures, including transcatheter aortic valve replacements (TAVR) and percutaneous endovascular aneurysm repair (pEVAR), often from vascular closure device (VCD) failure. We compared suture-only (SO) with suture and plug-based hybrid (HSP) vascular closure technique for vascular access haemostasis after percutaneous procedures such as TAVR and pEVAR. METHOD: We performed a systematic literature search of randomised controlled trials (RCT) and observational studies using PubMed, Embase, Cochrane Library, ScienceDirect, and ClinicalTrials.gov following the PRISMA guidelines. The study protocol was registered at PROSPERO (ID: CRD42024627875). We calculated the relative risk (RR) and 95% confidence interval (CI) for individual end points of vascular complications, bleeding risk, VCD failure, and mortality, using random-effects models to report overall effect sizes. RESULTS: Nine studies, including two RCTs and seven observational studies, comprising 3,765 patients (SO, 1,971; HSP, 1,790), were analysed. The SO strategy was associated with a significantly higher risk of vascular complications (RR 1.95; p<0.01), bleeding (RR 2.14; p=0.01), and VCD failure (RR 4.00; p<0.01) compared with the HSP technique. No significant difference was noted in all-cause mortality (RR 1.61; p=0.11) between the two groups, although the analysis was limited by the relatively small number of observed events and wide CIs. CONCLUSIONS: Use of the HSP technique for vascular access haemostasis after TAVR or pEVAR was associated with significantly lower rates of vascular complications, bleeding, and VCD failure compared with SO closure, without a significant difference in mortality.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers