The Impact of Prolonged Pre-Heart Transplantation Left Ventricular Assist Device on Post-Transplantation Outcomes.
Raden A D A Puspitarani, Stijn Legtenberg, Michiel E Erasmus, Jozine M Ter Maaten, Jan A Krikken, Stan A J van den Broek, Joep M Droogh, Arjan J F P Verhaegh,
University of Groningen, Department of Cardiology, University Medical Center Groningen, Groningen, The Netherlands. · University of Groningen, Department of Cardiothoracic Surgery, University Medical Center Groningen, Groningen, The Netherlands.
Key points
From the paper's conclusion- Prolonged LVAD support as bridge-to-transplantation showed no statistically significant differences with direct HTx in terms of post-HTx survival, rejection rates, and renal function despite minor differences in 1-year haemodynamic parameters.
Abstract
BACKGROUND: Durable mechanical circulatory support with a left ventricular assist device (LVAD) serves as bridge to heart transplantation (HTx) in patients with advanced heart failure. LVAD therapy is associated with improved outcomes, but has inherent limitations, including device-related complications. In this study, we aimed to evaluate the impact of prolonged LVAD support in patients who underwent HTx as compared to those without LVAD support. METHOD: We retrospectively analysed 148 HTx recipients at University Medical Center Groningen, the Netherlands (2007-2023): 52 with prior LVAD support and 96 direct HTx patients. Outcomes included post-HTx survival, rejection requiring treatment, 1-year cardiac haemodynamics, and need for kidney replacement therapy. RESULTS: Median LVAD duration was 757 days (range 16-2,113). The LVAD group had fewer females (21% vs 54%; p<0.001). After a median 3.5-year follow-up, post-HTx survival was similar between groups (hazard ratio 0.83; 95% confidence interval 0.40-1.6; p=0.52). No significant differences were observed in the incidence of rejection requiring therapy (p=0.91) nor need for kidney replacement therapy (p=0.05-0.42). At 1-year post-HTx, the LVAD group showed modestly elevated pulmonary capillary wedge pressure (12.7 vs 10.6 mmHg; p=0.03) and reduced cardiac index (3.0 vs 3.3 L/min/m2; p=0.03) compared to direct HTx recipients. CONCLUSIONS: Prolonged LVAD support as bridge-to-transplantation showed no statistically significant differences with direct HTx in terms of post-HTx survival, rejection rates, and renal function despite minor differences in 1-year haemodynamic parameters.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparable Rates of Severe Primary Graft DysfunctionAfter Heart Transplantation in Recipients With Prior LVAD or Other Cardiac Surgery: The Burden of Surgical Reentry.The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2026
- The interaction of age and time on durable left ventricular assist device and its effect on heart transplant outcomes.JTCVS open · 2026
- Nationwide Outcomes and Predictors of Mortality After Left Ventricular Assist Device Implantation in Korea: Insights From the Korean Registry for Mechanically Assisted Circulatory Support.Circulation reports · 2026
- Impact Of Ventricular Assist Device Use On Pediatric Heart Transplant Outcomes In A Linked Cohort Of The Advanced Cardiac Therapies Improving Outcomes Network (ACTION) And Pediatric Heart Transplant Society (PHTS) Databases.The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2026
- Short- and Long-Term Days Alive and Out of Hospital After Left Ventricular Assist Device Implantation.Journal of the American Heart Association · 2026
- Renal Decline Before Heart Transplantation in Left Ventricular Assist Device-Supported Recipients: United Network for Organ Sharing Analysis.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026