Validation of a Troponin I-Adapted Modified GRACE Score : A Cohort Study.
Dimitrios Delialis, Georgios Georgiopoulos, Christina Chrysochou, Luke Spray, Simon Kraler, Panagiotis Nastatos, Polyxeni Manifava, Christina Konstantaki,
Department of Clinical Therapeutics, National and Kapodistrian University of Athens Medical School, Athens, Greece. · Second Department of Cardiology, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece.
Key points
From the paper's conclusion- The updated ModGRACE model, incorporating continuous c/hs-TnI alongside re-estimated baseline predictors, demonstrated consistent improvements in risk reclassification and discrimination over original GRACE. Ultimately, these findings support the application of quantitative troponin data across different troponin assays, to improve prognostic accuracy and standardize risk assessment in clinical practice.
Abstract
INTRODUCTION: A modified Global Registry of Acute Coronary Events (modGRACE) model incorporating continuous rather than binary high-sensitivity troponin T data supersedes the performance of the original GRACE score. However, whether a similar prognostic gain can be achieved using contemporary-sensitive (cTnI) or high-sensitivity troponin I (hs-TnI) remains uncertain. METHODS: We analyzed data from 2 independent ACS cohorts of consecutively recruited patients: the Freeman cohort (Newcastle, United Kingdom; n = 2,991) and the Greek Study of ACS (GREECS; Greece; n = 1,630). Risk stratification using the original GRACE score and the modGRACE score incorporating continuous c/hs-TnI values. Model performance was assessed using Harrell's C-index and continuous net reclassification improvement (NRI). RESULTS: In the Freeman cohort, modGRACE showed improvements in discrimination for in-hospital (Harrell's C-index=0.871 vs 0.777) and 30-days mortality (0.848 vs 0.833), with significant improvement at 1-year (0.721 vs. 0.690, all p<0.05). Reclassification improved for in-hospital (NRI=0.67), 30-day (NRI=0.69), and 1-year mortality (NRI=0.49) (all p< .001). In the GREECS cohort, modGRACE showed improvements for discrimination in 30days-mortality (Harrell's C-index 0.778 vs 0.752) and cardiovascular-death at 20 years (0.682 vs. 0.653, p<0.05 for both); and improved risk reclassification for 30-day mortality (NRI, 0.56), 20-year cardiovascular mortality (NRI=0.85), and 20-year MACE (NRI=0.79) (all p<0.001). CONCLUSION: The updated ModGRACE model, incorporating continuous c/hs-TnI alongside re-estimated baseline predictors, demonstrated consistent improvements in risk reclassification and discrimination over original GRACE. Ultimately, these findings support the application of quantitative troponin data across different troponin assays, to improve prognostic accuracy and standardize risk assessment in clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Expanding the modified GRACE risk score to high-sensitivity troponin i: a multinational validation cohort studyEuropean Heart Journal · 2026
- High-sensitivity troponin and in-hospital mortality in non-ACS cardiac ICU admissions: a 14-year cohortEuropean Heart Journal · 2026
- The triglyceride-glucose index enhances GRACE score prognostication in type 2 myocardial infarction: a retrospective cohort studyFrontiers in Cardiovascular Medicine · 2026
- Clinical correlates, threshold sensitivity, and parsimonious modeling of high-sensitivity cardiac troponin I in health examination cohorts: a retrospective cross-sectional study with same-center temporal validation.Frontiers in medicine · 2026
- Serial Cardiac Troponin I Kinetics Do Not Improve Detection of Acute Cellular Rejection Beyond Concurrent Troponin Levels After Heart Transplantation.Journal of clinical medicine · 2026
- Galectin-3-enhanced prognostic models for major adverse cardiovascular events in Vietnamese patients with acute coronary syndrome: A prospective cohort study.Science progress · 2026