Acute cochlear bias and intracranial pressure in the presence of a perilymph fistula in gerbil.
Idir Djennaoui, Paul Avan
Laboratory of Sensory Biophysics, School of Medicine, University Clermont Auvergne, Clermont-Ferrand, France; Department of Otolaryngology Head and Neck Surgery, Hautepierre University Hospital, Strasbourg, France. · Laboratory of Sensory Biophysics, School of Medicine, University Clermont Auvergne, Clermont-Ferrand, France; Université Paris Cité, Institut Pasteur, AP-HP, INSERM, CNRS, Fondation Pour l'Audition, Institut de l'Audition, IHU reConnect, F-75012, Paris, France. Electronic address: paul.avan@uca.fr.
Key points
From the paper's conclusion- When CSF pressure was increased by 15 mmHg, the leak released perilymph overpressure while the endolymph compartment was likely still affected by increased CSF pressure.
Abstract
Since Tonndorf proposed that a bias applied to the elastic basilar membrane induces mechanical sensorineural hearing loss, several biasing methods have been tested, including low-frequency tones, electrochemical changes in the cochlea and application of a constant force to the bony cochlea. Attendant auditory changes likely stem from a common feature, a shift in the operating point (OP) of electromotile outer hair cells (OHCs). Here, the mechanical homeostasis of labyrinthine-fluid compartments was disrupted using cerebrospinal fluid (CSF) pressure steps combined with a perilymph fistula drilled near the oval window, a model of a real-life condition, in anesthetized Mongolian gerbils. When CSF pressure was increased by 15 mmHg, the leak released perilymph overpressure while the endolymph compartment was likely still affected by increased CSF pressure. Electrocochleography was monitored in 21 cases, and distortion-product otoacoustic emissions (DPOAEs) in 11 cases. Within seconds after CSF pressure increased, the summating potential SP rose up to >100% relative to the compound action potential (AP), lower-frequency AP thresholds increased by >30 dB, a spontaneous nystagmus appeared, and the balance between quadratic and cubic difference otoacoustic emissions was deeply modified. It took several minutes for the whole picture to complete and about one hour to disappear after CSF pressure release. These functional changes, reminiscent of symptoms of endolymphatic hydrops, suggested OHCs' OP shifts, in line with Tonndorf's view of mechanical sensorineural hearing loss.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Noninvasive indirect intracochlear pressure monitoring during cochlear implantationHearing Research · 2026
- Deterioration of auditory function and cochlear histopathology in blast-induced perilymphatic fistula in mice.Hearing research · 2026
- Post-lumbar Puncture Hearing Loss: A Rare Case of Reversible Presumed Secondary Endolymphatic Hydrops.The journal of international advanced otology · 2026
- An integrated computational model of the auditory periphery for intracochlear electrocochleography applications.The Journal of the Acoustical Society of America · 2026
- Popping sound and streaming water-like tinnitus in Cochlin-tomoprotein-confirmed perilymphatic fistula with antecedent barotrauma.Frontiers in neurology · 2026
- Finite Element Modeling of Organ of Cortis Throughout the Cochlea During Blast Wave Transmission.Military medicine · 2026