From the paper's conclusion
  • The addition of AEC to M-NBI significantly improved the real-time optical prediction of deep submucosal invasion of colonic neoplasms. (University Hospital Medical Information Network, Number UMIN000054451).

Abstract

BACKGROUND AND AIMS: The accurate optical prediction of deep submucosal invasion (T1b) is critical for selecting the appropriate treatment for colorectal neoplasia. Although magnifying narrow-band imaging (M-NBI) is widely used, diagnostic uncertainty remains, particularly in lesions for which deep invasion is suspected. We prospectively evaluated the incremental value of aceto-electronic chromoendoscopy (AEC) when it was added to M-NBI for real-time optical diagnosis. METHODS: This prospective multicenter study conducted at 11 Japanese institutions included patients with colorectal polyps measuring ≥10 mm. Real-time optical diagnosis was first performed using M-NBI and then reassessed with AEC. The diagnostic performance for predicting pathological T1b was evaluated against histopathology. Sensitivity, specificity, likelihood ratios, and the effect of the addition of AEC were analyzed. RESULTS: The overall diagnostic accuracy was 89.3%. The sensitivity and specificity for the prediction of deep submucosal invasion were 78.1% and 95.8%, respectively, with positive and negative likelihood ratios of 18.6 and 0.23, respectively. The pretest probability of T1b (21%) increased to approximately 83% after a positive optical diagnosis. When AEC was added, the specificity improved from 56.9% to 74.5%, and the overall accuracy improved from 60.3% to 77.6% (P < .0001), which reflects significant reclassification and a reduction in overdiagnosis. CONCLUSIONS: The addition of AEC to M-NBI significantly improved the real-time optical prediction of deep submucosal invasion of colonic neoplasms. (University Hospital Medical Information Network, Number UMIN000054451).

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers