Gait & posture

Inertial measurement unit-based gait analysis for objective assessment of vestibular rehabilitation.

Ivan Huuva, Erik Faergemann, Fredrik Öhberg, Solmaz Surano, Jonatan Salzer, Helena Grip

Department of Diagnostics and Intervention, Umeå University, Umeå, Sweden. Electronic address: ivan.huuva@regionvasterbotten.se. · Department of Clinical Sciences, Neurosciences, Umeå University, Umeå, Sweden. Electronic address: erik.faergemann@umu.se.

Key points

From the paper's conclusion
  • In conclusion, gait improvement was captured via IMU-based gait analysis, even when using a single sensor, supporting the clinical feasibility of using both single- and multi-sensor wearable systems for rehabilitation assessment.

Abstract

Acute vestibular syndrome (AVS), defined by sudden onset of dizziness, nausea, impaired balance and gait instability, severely affects normal daily activities. Vestibular rehabilitation alleviates the condition and facilitates the return to normal activities. This study assessed the rehabilitation process of 30 participants with AVS using Inertial Measurement Unit (IMU)-based gait analysis during timed 25-ft walk tests (T25FW) conducted at onset, after a 6-week rehabilitation program, and at a 12-week follow-up. 54 healthy controls also performed the T25FW on one occasion. Gait variables based on either five lower body sensors or only the pelvis sensor were investigated. Clinical variables: walking speed and Vertigo Symptom Scale-Short Form (VSS-SF) vertigo-balance subscale (VSS-V) were also recorded. Significant successive improvements in VSS-V were observed between all timepoints. Furthermore, walking speed, Gait Profile Score (GPS), pelvis GPS, and cadence decreased from onset to the end of the rehabilitation period, after which changes were not significant. Walking speed was slower for the AVS group at baseline (0.65 m/s, p < 0.0001) and at 12 weeks (1.13 m/s, p < 0.05) compared to controls (1.26 m/s). GPS, pelvis GPS, GPS asymmetry, and cadence were significantly greater compared to controls at baseline (6.8° vs. 4.4°, 3.6° vs. 2.6°, and 87 steps/min vs. 118 steps/min, respectively, p < 0.0001). GPS asymmetry was also higher at baseline compared to controls (1.40 steps/min vs. 0.80 steps/min, p < 0.05). In conclusion, gait improvement was captured via IMU-based gait analysis, even when using a single sensor, supporting the clinical feasibility of using both single- and multi-sensor wearable systems for rehabilitation assessment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Inertial measurement unit-based gait analysis for objective assessment of vestibular rehabilitation — Science Skim