Inertial measurement unit-based gait analysis for objective assessment of vestibular rehabilitation.
Ivan Huuva, Erik Faergemann, Fredrik Öhberg, Solmaz Surano, Jonatan Salzer, Helena Grip
Department of Diagnostics and Intervention, Umeå University, Umeå, Sweden. Electronic address: ivan.huuva@regionvasterbotten.se. · Department of Clinical Sciences, Neurosciences, Umeå University, Umeå, Sweden. Electronic address: erik.faergemann@umu.se.
Key points
From the paper's conclusion- In conclusion, gait improvement was captured via IMU-based gait analysis, even when using a single sensor, supporting the clinical feasibility of using both single- and multi-sensor wearable systems for rehabilitation assessment.
Abstract
Acute vestibular syndrome (AVS), defined by sudden onset of dizziness, nausea, impaired balance and gait instability, severely affects normal daily activities. Vestibular rehabilitation alleviates the condition and facilitates the return to normal activities. This study assessed the rehabilitation process of 30 participants with AVS using Inertial Measurement Unit (IMU)-based gait analysis during timed 25-ft walk tests (T25FW) conducted at onset, after a 6-week rehabilitation program, and at a 12-week follow-up. 54 healthy controls also performed the T25FW on one occasion. Gait variables based on either five lower body sensors or only the pelvis sensor were investigated. Clinical variables: walking speed and Vertigo Symptom Scale-Short Form (VSS-SF) vertigo-balance subscale (VSS-V) were also recorded. Significant successive improvements in VSS-V were observed between all timepoints. Furthermore, walking speed, Gait Profile Score (GPS), pelvis GPS, and cadence decreased from onset to the end of the rehabilitation period, after which changes were not significant. Walking speed was slower for the AVS group at baseline (0.65 m/s, p < 0.0001) and at 12 weeks (1.13 m/s, p < 0.05) compared to controls (1.26 m/s). GPS, pelvis GPS, GPS asymmetry, and cadence were significantly greater compared to controls at baseline (6.8° vs. 4.4°, 3.6° vs. 2.6°, and 87 steps/min vs. 118 steps/min, respectively, p < 0.0001). GPS asymmetry was also higher at baseline compared to controls (1.40 steps/min vs. 0.80 steps/min, p < 0.05). In conclusion, gait improvement was captured via IMU-based gait analysis, even when using a single sensor, supporting the clinical feasibility of using both single- and multi-sensor wearable systems for rehabilitation assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Technical evaluation of transport-derived movement trajectories during knee osteoarthritis rehabilitation.Medical engineering & physics · 2026
- Concurrent Validity and Between-System Agreement of a Commercial Wearable Inertial Sensor System for Gait and Postural Sway Assessment in Progressive Supranuclear Palsy.Sensors (Basel, Switzerland) · 2026
- An exploration of self-evaluation of induced temporal and spatial gait asymmetry in neurotypical young adults.Gait & posture · 2026
- Assessing Sensory Reweighting During Walking Using the Sensory Integration Gait Evaluation in Independently Ambulatory Adults.Journal of visualized experiments : JoVE · 2026
- In-Home Free-Living Gait Monitoring Using a Single Lumbar IMU Reveals Nonlinear Complexity Changes During Intensive Stroke Rehabilitation.Sensors (Basel, Switzerland) · 2026
- Short-term effects of real-time feedback gait training using inertial measurement units on gait parameters in older inpatients: a within-subject pilot study.BMC geriatrics · 2026