Foot (Edinburgh, Scotland)

Comparison of Achilles tendon loading between rocker-soled and advanced footwear technology shoes during running in healthy individuals.

Kimika Sato, Tomoya Takabayashi, Honoka Nishiguchi, Takeru Tsunoda, Takanori Kikumoto, Masayoshi Kubo

Department of Physical Therapy, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-Ku, Niigata City, Niigata 950-3198, Japan. Electronic address: rpa22077@nuhw.ac.jp. · Department of Physical Therapy, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-Ku, Niigata City, Niigata 950-3198, Japan; Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-Ku, Niigata City, Niigata 950-3198, Japan. Electronic address: takabayashi@nuhw.ac.jp.

Key points

From the paper's conclusion
  • Rocker shoes reduced Achilles tendon loading during running, whereas AFT shoes did not significantly alter Achilles tendon loading compared with neutral shoes. The reduction in tendon loading was accompanied by a lower peak anterior ground reaction force, which may reflect reduced propulsive demand at the ankle joint. Rocker shoes may therefore be beneficial for reducing mechanical loading of the Achilles tendon during running.

Abstract

BACKGROUND: Achilles tendinopathy is a common running-related injury, and footwear characteristics may influence Achilles tendon loading. This study investigated the effects of rocker shoes and advanced footwear technology (AFT) shoes on Achilles tendon (AT) force during running. METHODS: Nineteen healthy adult males with normal foot posture performed rearfoot strike running at a controlled speed under three footwear conditions: neutral, rocker, and AFT shoes. Peak AT force, AT force impulse per step, ankle joint angle, anterior ground reaction force, and stance time were compared among the three conditions. RESULTS: No significant differences in ankle joint angle or stance time were observed among the footwear conditions. Compared with neutral and AFT shoes, rocker shoes significantly reduced peak AT force, AT force impulse per step, and peak anterior ground reaction force. No significant differences were observed between AFT and neutral shoes for any AT force-related variable. CONCLUSIONS: Rocker shoes reduced Achilles tendon loading during running, whereas AFT shoes did not significantly alter Achilles tendon loading compared with neutral shoes. The reduction in tendon loading was accompanied by a lower peak anterior ground reaction force, which may reflect reduced propulsive demand at the ankle joint. Rocker shoes may therefore be beneficial for reducing mechanical loading of the Achilles tendon during running.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers