The French journal of urology

Impact of Semirigid Ureteroscope Caliber on Perioperative Outcomes and Surgeon Stress: A Prospective Randomized Study.

Gökhan Sahin, Büşra Şahin, Hakan Görkem Kazici, Arif Kol, Mustafa Tipirdamaz

Aydin State Hospital, Department Of Urology, Aydin, Turkey. Electronic address: gokhansahinn7510@gmail.com. · Aydin Adnan Menderes University, Department Of Surgical Nursing Aydin, Turkey. Electronic address: busratipirdamaz@gmail.com.

Randomised · n=130

Key points

From the paper's conclusion
  • Small- and standard-caliber ureteroscopes showed no significant difference in SFRs, but standard-caliber instruments were associated with higher rates of balloon dilation, ureteral injury, and JJ stent placement, as well as increased surgeon-reported stress. Ureteroscope caliber may influence both technical outcomes and the surgeon's intraoperative experience, although stress findings remain exploratory.

Abstract

INTRODUCTION: To compare the effectiveness and safety of small- and standard-caliber semirigid ureteroscopes for ureteral stones and evaluate whether caliber correlates with intraoperative surgeon stress. MATERIAL AND METHODS: In this prospective randomized study, 130 patients underwent ureterorenoscopy using either a 4.5-6.5 Fr (thin) or 8-9.8 Fr (standard) semirigid ureteroscope. The primary endpoint was the stone-free rate (SFR); secondary endpoints included perioperative outcomes and surgeon stress. Stress was assessed using the State-Trait Anxiety Inventory Form TX-1 (STAI-TX1) before and after each procedure, with increased stress defined as ΔSTAI-TX1 > 0. Multivariable logistic regression identified independent predictors of increased stress. RESULTS: Baseline characteristics were comparable. SFRs did not differ significantly between the thin- and standard-caliber groups (92.3% vs. 86.2%, p = 0.25). Balloon dilation (32.3% vs. 4.6%, p < 0.01), ureteral injury (21.5% vs. 4.6%, p = 0.004), and JJ stent placement (46.2% vs. 26.2%, p = 0.018) were more frequent in the standard-caliber group. Increased surgeon stress occurred more often with standard-caliber ureteroscopes (27.7% vs. 9.2%, p = 0.007). Multivariable analysis confirmed that standard-caliber use was independently associated with increased stress (adjusted OR 3.11, 95% CI 1.09-8.84, p = 0.033), which remained significant in a Firth penalized sensitivity analysis (adjusted OR 2.94, 95% CI 1.06-8.17, p = 0.037). CONCLUSION: Small- and standard-caliber ureteroscopes showed no significant difference in SFRs, but standard-caliber instruments were associated with higher rates of balloon dilation, ureteral injury, and JJ stent placement, as well as increased surgeon-reported stress. Ureteroscope caliber may influence both technical outcomes and the surgeon's intraoperative experience, although stress findings remain exploratory.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Impact of Semirigid Ureteroscope Caliber on Perioperative Outcomes and Surgeon Stress: A Prospective Randomized Study — Science Skim