Reconstructing long-time voltage relaxation from short pulse tests for faster battery testing and modeling

Jun Yuan, Shanling Ji, Leon Merker, Leah Nuss, Bojing Zhang, Qiaomin Ke, Helge Sören Stein

Munich Center for Machine Learning

Key points

From the paper's conclusion
  • The reconstruction was especially consistent over the mid-SOC range (20–80% SOC), with relatively larger deviations observed near the voltage cut-offs.

Abstract

The galvanostatic intermittent titration technique (GITT) is a widely used method for obtaining open-circuit voltage (OCV) profiles and kinetic information in rechargeable batteries. However, its practical use is limited by the long relaxation period required after each current pulse. This study proposes a physics-consistent short-window extrapolation method to reconstruct long-time relaxation behavior from only minutes of post-pulse data. Based on this framework, two pulse-wise OCV extraction strategies, namely threshold-based convergence and time-based extrapolation, are evaluated. The utility of reconstructed relaxation trajectories for downstream equivalent-circuit-model (ECM)-based dynamic battery modeling is also assessed. The method was evaluated using more than 5.7 k pulses across 8 different rest-duration protocols. Using 10 min of measured relaxation data, the threshold-based convergence yielded RMSE values of 4.35 mV during charge and 8.98 mV during discharge relative to the measured 3 h relaxation, reducing the required relaxation time from 180 min to 10 min. For downstream modified 2-RC ECM analysis, the time-based extrapolation-assisted framework reduced the mean absolute error by 78% relative to direct identification from 10 min data, and achieved accuracy comparable to direct identification from 1 h relaxation data while using only 1/6 of the measured relaxation time. Independent validation on five additional commercial cells confirmed that reconstruction-assisted ECM consistently reduces the error relative to direct ECM identification. The reconstruction was especially consistent over the mid-SOC range (20–80% SOC), with relatively larger deviations observed near the voltage cut-offs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers