Environmental research

A wireless and passive RFID-based sensing system for the detection of Cd2+ in soil: A novel approach for onsite detection of hazardous metals.

Zuozheng Ding, Hu Shi, Yihan Yao, Yu Han, Jianqing Shen, Guowei Fan, Chengxiang Duan, Xiangfang Tang,

College of Artificial Intelligence, Nanjing Agricultural University, Nanjing, 210031, PR China. · College of Engineering, Nanjing Agricultural University, Nanjing, 210031, PR China.

Key points

From the paper's conclusion
  • This study presented a wireless and passive radio frequency identification (RFID)-based sensing system for the rapid onsite detection of Cd2+ in soil.

Abstract

Cd2+ pollution seriously endangers ecological safety and human health, and it is of great importance to develop a rapid onsite detection strategy for Cd2+. This study presented a wireless and passive radio frequency identification (RFID)-based sensing system for the rapid onsite detection of Cd2+ in soil. The sensing system comprised three core components: a polyaniline/cysteine (PANI/Cys) chemiresistive sensing element, an ultra-high frequency (UHF) RFID tag (which collectively formed the RF-tagged sensor), and a dedicated sensing platform. The sensing principle relies on the specific chelation between Cys and Cd2+, which changes the resistance of the PANI/Cys sensing element. The RF-tagged sensor responds to the resistance variation through impedance mismatch. A wireless and passive detection method based on impedance mismatch was developed: the sensing platform captured variations in the minimum response power (MRP) of the RF module induced by this impedance mismatch, and a segmented linear correlation between MRP and Cd2+ concentration was well established over the ranges of 1-10 ppb (μg/L) and 10-100 ppb (μg/L), with a limit of detection (LoD) of 3.81 ppb (μg/L) for the detection of Cd2+. In the analysis of real soil samples, all RMSE values were no more than 10 μg/kg, and the sensing system enabled rapid onsite detection within 30-120 s. It should be noted that this work required soil extraction pretreatment and could not realize direct onsite detection of solid soil matrices. Nevertheless, it offered a practical tool for soil pollution risk assessment and exhibited considerable potential for soil environmental management.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A wireless and passive RFID-based sensing system for the detection of Cd2+ in soil: A novel approach for onsite detection of hazardous metals — Science Skim