Comprehensive Characterization of Bioaerosol Microbial Communities, ARG, and Occupational Exposure Risks in WWTP and Comprehensive Landfill.
Song Zhang, Jialin Li, Lirong Gao, Wenyu Zhang, Dong Wu, Yanjie Wang
Shanghai Engineering Research Center of Biotransformation of Organic Solid Waste, School of Ecological and Environmental Sciences, East China Normal University, Shanghai 200241, China; College of Public Health, Zhengzhou University, Zhengzhou 450001, China. · College of Public Health, Zhengzhou University, Zhengzhou 450001, China.
Key points
From the paper's conclusion- Therefore, we integrated 16S rRNA gene amplicon sequencing, high-throughput quantitative PCR, quantitative microbial risk assessment, exposure-dose estimation, and machine learning to compare microbial communities, antibiotic resistance genes and mobile genetic elements (ARGs/MGEs), and estimated occupational exposure levels at a wastewater treatment plant (XQ) and an integrated solid waste treatm
Abstract
In the sewage treatment plant and landfill in the same area, the differences in transmission characteristics of potential pathogenic microorganisms and antibiotic resistance genes/movable genetic elements (ARGs/MGEs) mediated by bioaerosols have not been fully studied. Therefore, we integrated 16S rRNA gene amplicon sequencing, high-throughput quantitative PCR, quantitative microbial risk assessment, exposure-dose estimation, and machine learning to compare microbial communities, antibiotic resistance genes and mobile genetic elements (ARGs/MGEs), and estimated occupational exposure levels at a wastewater treatment plant (XQ) and an integrated solid waste treatment facility (DP) in Central China. The mean culturable bacterial concentration was 3.4-fold higher at DP than at XQ (1726 CFU/m3, 502 CFU/m3), and proportion of fine biogenic particles was also higher at DP (27%, 15%). In contrast, mean airborne concentration of ARGs/MGEs was substantially higher at XQ than at DP (5462 copies/m3, 584 copies/m3), resulting in a higher estimated inhalation exposure dose at XQ. The dominant resistance determinants were ermC, dhps, and intI1 at XQ, and cmxA, tnpA-05, and lnuA-01 at DP. Machine learning analysis identified Faecalibacterium as an important microbial feature distinguishing solid waste bioaerosols, whereas blaPAO was among most influential ARG features associated with XQ bioaerosols. Partial least squares regression revealed extensive covariation between bacterial genera and resistance determinants. Achromobacter was positively associated with ermX at XQ and with intI1 at DP, although these associations do not establish direct host-gene relationships. Overall, two facilities showed contrasting bioaerosol exposure profiles, characterized by higher bacterial and fine-particle levels at DP and higher ARG/MGE exposure estimates at XQ. These findings support facility-specific occupational aerosol control and monitoring strategies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Wastewater Air Plasmidome Harbors Antibiotic, Metal, and Biocide Resistance DeterminantsACS ES&T Air · 2026
- Bioaerosolization across 15 wastewater treatment plants: Decoupling between airborne and wastewater microbial concentrations.Water research · 2026
- Framework for Assessing the Potential Health Risks of Airborne Antibiotic Resistance Genes.Environment & health (Washington, D.C.) · 2026
- Aeration change from horizontal brush to fine bubble substantially reduces the emission of inhalable antibiotic resistome from wastewater to air.Journal of hazardous materials · 2026
- Biofilm Contributions of Bacterial Pathogens and Antimicrobial Resistance Genes to Wastewater Surveillance Signal at the Hospital ScaleACS ES&T Water · 2026
- Source-Resolved Wastewater Metagenomics Reveals Distinct Resistome and Virulome Landscapes Across an Urban Wastewater Continuum.Antibiotics (Basel, Switzerland) · 2026