Assessing ambient air pollution at early childhood development centres near coal-fired power plants and coal mines in Mpumalanga, South Africa.
Y P Mkunyana, T Kootbodien, N Mahlangeni, C Y Wright, M Jagarnath, R Street
Environment & Health Research Unit, South African Medical Research Council, Cape Town, South Africa. Electronic address: yonela.mkunyana@mrc.ac.za. · Environment & Health Research Unit, South African Medical Research Council, Cape Town, South Africa; Centre for Environmental and Occupational Health Research, School of Public Health and Family Medicine, University of Cape Town, Cape Town, South Africa.
Key points
From the paper's conclusion- These findings suggest potential pollution screening zones at approximately 40 km around CFPPs and 20 km around coal mines.
Abstract
Air pollution from coal-fired power plants (CFPPs) and coal mines remains a major environmental health concern, particularly for young children. The aim of this study was to characterize the spatial distribution of Early Childhood Development (ECD) centres within potential ambient air pollution zones, specifically areas surrounding CFPPs and coal mines in Mpumalanga, South Africa. Satellite-derived and ground-measured ambient air quality data for 2021 were obtained and compared against the South African National Ambient Air Quality Standards (SANAAQS) and the World Health Organization (WHO) air quality guidelines. Ambient pollutant concentrations were evaluated at ECDs across 10 km incremental distances from potential emission sources using buffer, hotspot, and distance-decay analyses. Sensitivity analyses were conducted to assess the influence of alternative neighbourhood sizes (k) and compare linear, restricted cubic spline and 10 km distance band models. The results were compared to identify the appropriate approach for characterising spatial pollution patterns and informing the delineation of proposed screening zones. Monthly and seasonal summaries of ground-monitored NO2, SO2, and PM2.5 concentrations were used to characterise temporal variation of pollutants. Of the 2,894 ECD centres, 39 were located within 10 km of coal-fired power plants (CFPPs) and 1,484 within 10 km of coal mines. Ambient concentrations varied spatially and seasonally, with winter peaks and higher concentrations observed in Nkangala and Gert Sibande districts. Analyses showed that pollutant concentrations declined with increasing distance from both sources. Around CFPPs, the largest decline occurred beyond 40 km, while the decline was observed beyond 20 km from coal mines. These findings suggest potential pollution screening zones at approximately 40 km around CFPPs and 20 km around coal mines. These observations were similar across linear and other models for NO2 and SO2. These zones are empirical and study-area specific and should therefore be used as planning tools and not definitive thresholds.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prenatal and infant exposure to emissions from a coal mine fire and airway inflammation in childhood: the Hazelwood Early Life Follow-up (ELF) studyBMC Pulmonary Medicine · 2026
- Early Life Ambient Air Pollution and Child Neurodevelopment: Critical Review of Cohort Evidence.Journal of xenobiotics · 2026
- Short-term effects of ambient air pollution exposure on respiratory hospitalizations among children in the State of Mexico.Environmental science and pollution research international · 2026
- Environmental exposures and pediatric kidney healthPediatric Research · 2026
- Associations between air pollution and pediatric pneumonia incidence in Ulaanbaatar, Mongolia: age and sex susceptibility.Journal of thoracic disease · 2026
- Inequalities and indoor air pollution: a prospective observational study of particulate matter (PM2.5) levels in 309 UK homes from the Born in Bradford cohort studyBMC Public Health · 2025