Environmental pollution (Barking, Essex : 1987)

Fate, risk and removal of legacy and emerging PFAS in the drinking water system of the Pearl River Delta: From source to tap using a comprehensive analysis and prioritization approach.

Pan Zhu, Xuan Liu, Guanging Su, Changyun He, Jing Deng, Qiuxia Chen, Xiuhua Zhong, Min Li,

Guangdong Provincial Center for Disease Control and Prevention, Guangzhou, 510430, P. R. China. · Guangdong Provincial Center for Disease Control and Prevention, Guangzhou, 510430, P. R. China; Guangdong Basic Research Center of Excellence for Ecological Security and Green Development, Key Laboratory of City Cluster Environmental Safety and Green Development of the Ministry of Education, School of Environmental Science and Engineering, Guangdong University of Technology, Guangzhou, 510006, P. R. China.

Key points

From the paper's conclusion
  • We analyzed 50 legacy and emerging PFAS in 108 water samples from 18 drinking water treatment plants (DWTPs) in the Pearl River Delta across wet and dry seasons.

Abstract

Per- and polyfluoroalkyl substances (PFAS) threaten drinking water safety. However, integrated assessments of occurrence, treatment, sources, and health-risk prioritization remain limited. We analyzed 50 legacy and emerging PFAS in 108 water samples from 18 drinking water treatment plants (DWTPs) in the Pearl River Delta across wet and dry seasons. Mean ∑50 PFAS concentrations in raw water were 4.98 ng/L (North River) and 2.07 ng/L (West River). All target PFAS were detected at least once, and 21 compounds had detection frequencies > 50%. HFPO-DA and HFPO-TA were first detected in North River raw water. Concentrations were higher in densely populated industrial areas (p < 0.05), and although no basin-wide seasonal difference was found, the West River had significantly higher concentrations in the dry season (p ≤ 0.001). Positive matrix factorization attributed contamination in the studied basin primarily to electroplating discharge (29.1%) and fluorochemical manufacturing (27.2%). Conventional DWTPs showed no consistent PFAS apparent remove efficiencies (-56.8 to -13.8%) observed in same case. GAC-equipped DWTPs performed better than PAC-equipped DWTPs, whereas ultrafiltration and chlorination had limited effects. Risks from the evaluated compounds were within acceptable thresholds, although children showed 2.1-2.8-fold higher hazard quotients, and ToxPi prioritized PFOS, PFBA, PFOA, PFNA, and PFHpA. These findings support expanding regulatory and monitoring priorities beyond legacy PFAS to include short-chain and emerging alternatives.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Fate, risk and removal of legacy and emerging PFAS in the drinking water system of the Pearl River Delta: From source to tap using a comprehensive analysis and prioritization approach — Science Skim