Radiometric Calibration for Multi-Satellite HCHO Retrievals: Improving Accuracy, Consistency and Global Daily Coverage.
Xingyue Zhao, Wenjing Su, Xiaohan Wang, Chengxin Zhang, Hongri Hou, Jingkai Xue, Cheng Liu
School of Environmental Science and Optoelectronic Technology, University of Science and Technology of China, Hefei 230026, China; Key Laboratory of Environmental Optics and Technology, Anhui Institute Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China. · Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China. Electronic address: wjsu@iue.ac.cn.
Key points
From the paper's conclusion- The results show that in the early post-launch phase, the radiometric calibration error of GF5(01A) (1.87%) was larger than that of DQ1 (1.61%) and OMI (1.08%).
Abstract
Formaldehyde (HCHO) is a recognized toxic pollutant and plays a significant role in atmospheric complex pollution. High spatiotemporal resolution and long-term continuous HCHO monitoring are essential for tracking air quality and anthropogenic emissions. However, such monitoring is limited by spectral radiometric accuracy which varies due to differences in sensor performance and in-orbit degradation. We proposed a novel radiometric calibration approach to correct spectral biases and applies it to afternoon-crossing platforms, including China's satellites GF5(01A) and DQ1, as well as the Ozone Monitoring Instrument (OMI). The results show that in the early post-launch phase, the radiometric calibration error of GF5(01A) (1.87%) was larger than that of DQ1 (1.61%) and OMI (1.08%). These errors significantly affect the accuracy and validity of HCHO retrievals, especially for GF5(01A). Applying our proposed method can markedly improve the retrieval precision and achieve a high level of consistency among HCHO retrieval from multiple satellites. Against MAX-DOAS, the correlation coefficient (R) increased from 0.34 to 0.68 for GF5(01A) and from 0.57 to 0.65 for DQ1. Against Pandora, R increased from 0.29 to 0.86 and from 0.72 to 0.80, respectively, while the normalized mean bias (NMB) decreased from +57.6% to +15.2% and from +36.2% to +20.0%. The method also improved agreement between the two satellites, increasing their correlation from 0.79 to 0.94 and bringing the inter-sensor NMB from -13.7% to -2.5%. On this basis, we performed data fusion and collaborative observation using the two China's satellites, increasing daily coverage by approximately 10%. Applied to OMI, the method reduced spurious long-term drift in HCHO retrievals from non-anomalous pixels over the Pacific, supporting more consistent long-term monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deriving a proxy for highly reactive VOCs from satellite formaldehyde: Application to a Chinese megaregion.Journal of hazardous materials · 2026
- Intercomparison of MAX-DOAS, FTIR and direct sun HCHO vertical columns at Xianghe, ChinaAtmospheric measurement techniques · 2026
- Evaluating vertically resolved Pandora formaldehyde retrievals using airborne and ground-based in situ measurementsAtmospheric Measurement Techniques · 2026
- Adaptive Reference Spectrum-Based Spectral and Radiometric Calibration of GF-5B GMI Using Physics-Based Radiative Transfer SimulationRemote Sensing · 2026
- Selective calibration of direct OCO-2 level-1B XCO2 retrieval across held-out TCCON stationsFrontiers in Earth Science · 2026
- Full field of view temporal calibration for the directional polarimetric camera onboard the GaoFen-5 (02) satellite based on a data reconstruction method.Applied optics · 2026