European journal of surgical oncology : the journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology

MRI-based comparison of skin flap thickness and short-term oncologic outcomes after manual versus robotic nipple-sparing mastectomy.

Je Min Choi, Sung Ui Jung, Jin Hyuk Choi, Ku Sang Kim

Department of Surgery, Kosin University Gospel Hospital, Busan, South Korea. Electronic address: 23gaze@gmail.com. · Department of Surgery, Kosin University Gospel Hospital, Busan, South Korea.

Observational · n=222

Key points

From the paper's conclusion
  • Robotic nipple-sparing mastectomy was not associated with increased postoperative MRI-based skin flap thickness compared with manual nipple-sparing mastectomy, and no apparent differences in short-term recurrence or postoperative complication rate were observed during the follow-up period. However, the short-term follow-up duration, limited number of recurrence events, the significant between-group difference in PMRT use and its variable timing relative to postoperative MRI, and the indirect nature of skin flap thickness as a surrogate marker limit the interpretation of oncologic outcomes. Further studies with longer follow-up are required to clarify long-term oncologic outcomes.

Abstract

BACKGROUND: Robotic nipple-sparing mastectomy (R-NSM) has been increasingly adopted because of its potential cosmetic advantages. However, concerns remain regarding thicker skin flaps, residual breast tissue, and oncologic safety compared with manual nipple-sparing mastectomy (M-NSM). This study aimed to compare skin flap thickness and clinical outcomes between M-NSM and R-NSM using postoperative magnetic resonance imaging (MRI). METHODS: A total of 222 patients who underwent M-NSM (n = 88) or R-NSM (n = 134) with immediate breast reconstruction were retrospectively reviewed. Skin flap thickness was measured on postoperative breast MRI performed approximately 6 months after surgery. Measurements were performed at the subareolar point and peripheral point (mean value of the four measurements located 2 cm from the nipple in the 12-, 3-, 6-, and 9-o'clock directions). Measurements were performed on postoperative T1-weighted breast MRI by two breast surgeons independently. Recurrence and postoperative complications were also evaluated and compared between the two groups. RESULTS: There was no statistically significant difference in skin flap thickness between the M-NSM and R-NSM groups at either the subareolar point (P = 0.155) or the peripheral point (P = 0.349). Overall recurrence rates were not significantly different between the two groups (P = 1.000), and the postoperative complication rate also showed no statistically significant difference between the two groups (P = 0.853). The median follow-up periods were 659 days in the M-NSM group and 639 days in the R-NSM group. The proportion of patients who received post-mastectomy radiotherapy (PMRT) was significantly higher in the M-NSM group than in the R-NSM group (P < 0.001), which represents a potential confounding factor in the interpretation of both the recurrence outcomes and the measured skin flap thickness. CONCLUSION: Robotic nipple-sparing mastectomy was not associated with increased postoperative MRI-based skin flap thickness compared with manual nipple-sparing mastectomy, and no apparent differences in short-term recurrence or postoperative complication rate were observed during the follow-up period. However, the short-term follow-up duration, limited number of recurrence events, the significant between-group difference in PMRT use and its variable timing relative to postoperative MRI, and the indirect nature of skin flap thickness as a surrogate marker limit the interpretation of oncologic outcomes. Further studies with longer follow-up are required to clarify long-term oncologic outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers