Key points
From the paper's conclusion- Specialized interpretation was associated with higher diagnostic yield for TZ lesions, particularly PI-RADS 4. Reader-dependent application of the erased-margins criterion is a candidate mechanism requiring confirmation and a potential training target rather than a stand-alone rule; prospective external validation is needed.
Abstract
BACKGROUND: PI-RADS scoring of transition zone (TZ) lesions is strongly reader-dependent, particularly in the PI-RADS 4 category. We compared diagnostic performance and inter-reader agreement between a specialized high-volume center and non-specialized referring centers. METHODS: Overall, 315 men with a TZ lesion scored PI-RADS ≥ 3 underwent MRI-guided in-bore biopsy and were stratified by interpreting site (non-specialized vs specialized). The erased-margins criterion was reassessed centrally by one specialized-center reader (the biopsy operator) and, in a 125-lesion subset, by three independent readers. RESULTS: Positive predictive value for clinically significant cancer (csPCa, Grade Group ≥ 2) at PI-RADS ≥ 4 was higher in the specialized cohort (43.3% vs 29.5%, p = 0.015). For PI-RADS 4 lesions, detection of any cancer was 76.9% vs 42.6% (p < 0.001), but not significantly different for csPCa (32.1% vs 22.8%, p = 0.16). On central reassessment, non-specialized centers had more often assigned PI-RADS 4 to lesions without erased margins (50% vs 35%, p = 0.048), a difference not replicated by the three independent readers. Agreement on PI-RADS category was substantial within and moderate between centers (κ 0.68 vs 0.43-0.49); agreement on the erased-margins criterion was fair-to-moderate (Fleiss κ 0.30), and its discriminative value decreased with decreasing expertise (AUC 0.82, 0.75, 0.70), largely reflecting lesion identification. The central reassessment did not outperform blinded readers (AUC 0.69). CONCLUSION: Specialized interpretation was associated with higher diagnostic yield for TZ lesions, particularly PI-RADS 4. Reader-dependent application of the erased-margins criterion is a candidate mechanism requiring confirmation and a potential training target rather than a stand-alone rule; prospective external validation is needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Whole-Gland and Transition Zone PSA Density in Predicting Clinically Significant Prostate Cancer in PI-RADS 3 Lesions.The Prostate · 2026
- Zonal PSA Density Strategies and the Incremental Yield of Systematic Biopsy in Men with PI-RADS 3 Lesions: A Single-Center Retrospective Cohort Study.Diagnostics (Basel, Switzerland) · 2026
- Navigating PI-RADS 3 Lesions: Reducing Uncertainty and Guiding Prostate Cancer Diagnostic Decision Making.Radiographics : a review publication of the Radiological Society of North America, Inc · 2026
- An Assessment of PI-RADS v2.1: Inter-Reader Agreement, Diagnostic Accuracy, and the Added Value of PSA Density in Prostate Cancer Prediction.Diagnostics (Basel, Switzerland) · 2026
- Impact of VI-RADS quality score on VI-RADS diagnostic performance for muscle invasion: the role of tumor size and reader experience.European radiology · 2026
- Risk Stratification of Prostate Imaging Reporting and Data System (PI-RADS 3) Lesions in the Peripheral and Transition Zones Using Clinical and Quantitative MRI Markers.Journal of magnetic resonance imaging : JMRI · 2026