European journal of radiology

High-resolution proton-density MRI versus time-of-flight MRA for visualizing small circle-of-Willis arteries: Comparison with three-dimensional rotational angiography.

Dongjun Lee, Boseong Kwon, Seung Chai Jung, Jungbok Lee, Yunsun Song, Jae Sung Ahn, Keum Mi Choi, Narim Lee

Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea. · Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea. Electronic address: dynamics79@gmail.com.

Observational · n=183

Key points

From the paper's conclusion
  • HR-PD depicted the SHA, Pcom, AChA, and Acom better than Source-MRA, with the largest differences at the SHA and Pcom. The OA was depicted less well on HR-PD than on Source-MRA.

Abstract

PURPOSE: High-resolution proton-density imaging (HR-PD) is a noninvasive technique for visualizing small intracranial arteries. We compared visualization of small arteries of the circle-of-Willis between HR-PD and high-resolution time-of-flight MR angiography source images (Source-MRA), with three-dimensional rotational angiography source images (Source-3D RA) as a comparator. METHODS: This retrospective study included 183 patients (mean age, 55.6 ± 11.6 years; 140 women) evaluated between November 2022 and July 2024. On a 3-point scale, two readers scored the superior hypophyseal (SHA), ophthalmic (OA), posterior communicating (Pcom), anterior choroidal (AChA), and anterior communicating (Acom) arteries on HR-PD and Source-MRA, and a third reader scored Source-3D RA. Artery-specific HR-PD versus Source-MRA differences were estimated with patient-clustered generalized estimating equations. P values were Holm-adjusted. Comparisons with Source-3D RA and interreader agreement (Gwet's AC2) were summarized. RESULTS: HR-PD scored higher than Source-MRA for the SHA (net proportion of sets scored higher on HR-PD, 0.48; 95% confidence interval [CI]: 0.43, 0.54), Pcom, AChA, and Acom (0.31, 0.07, and 0.11, respectively) and lower for the OA (-0.69; 95% CI: -0.74, -0.64; Holm-adjusted P < 0.001 for all five arteries). Relative to Source-3D RA, the net proportion was 0.25 (SHA), 0.22 (Pcom), -0.02 (AChA), 0.06 (Acom), and - 0.80 (OA). AC2 for HR-PD was 0.58 (SHA), 0.34 (OA), and 0.93-0.97 otherwise. CONCLUSION: HR-PD depicted the SHA, Pcom, AChA, and Acom better than Source-MRA, with the largest differences at the SHA and Pcom. The OA was depicted less well on HR-PD than on Source-MRA.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers