High-resolution proton-density MRI versus time-of-flight MRA for visualizing small circle-of-Willis arteries: Comparison with three-dimensional rotational angiography.
Dongjun Lee, Boseong Kwon, Seung Chai Jung, Jungbok Lee, Yunsun Song, Jae Sung Ahn, Keum Mi Choi, Narim Lee
Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea. · Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea. Electronic address: dynamics79@gmail.com.
Key points
From the paper's conclusion- HR-PD depicted the SHA, Pcom, AChA, and Acom better than Source-MRA, with the largest differences at the SHA and Pcom. The OA was depicted less well on HR-PD than on Source-MRA.
Abstract
PURPOSE: High-resolution proton-density imaging (HR-PD) is a noninvasive technique for visualizing small intracranial arteries. We compared visualization of small arteries of the circle-of-Willis between HR-PD and high-resolution time-of-flight MR angiography source images (Source-MRA), with three-dimensional rotational angiography source images (Source-3D RA) as a comparator. METHODS: This retrospective study included 183 patients (mean age, 55.6 ± 11.6 years; 140 women) evaluated between November 2022 and July 2024. On a 3-point scale, two readers scored the superior hypophyseal (SHA), ophthalmic (OA), posterior communicating (Pcom), anterior choroidal (AChA), and anterior communicating (Acom) arteries on HR-PD and Source-MRA, and a third reader scored Source-3D RA. Artery-specific HR-PD versus Source-MRA differences were estimated with patient-clustered generalized estimating equations. P values were Holm-adjusted. Comparisons with Source-3D RA and interreader agreement (Gwet's AC2) were summarized. RESULTS: HR-PD scored higher than Source-MRA for the SHA (net proportion of sets scored higher on HR-PD, 0.48; 95% confidence interval [CI]: 0.43, 0.54), Pcom, AChA, and Acom (0.31, 0.07, and 0.11, respectively) and lower for the OA (-0.69; 95% CI: -0.74, -0.64; Holm-adjusted P < 0.001 for all five arteries). Relative to Source-3D RA, the net proportion was 0.25 (SHA), 0.22 (Pcom), -0.02 (AChA), 0.06 (Acom), and - 0.80 (OA). AC2 for HR-PD was 0.58 (SHA), 0.34 (OA), and 0.93-0.97 otherwise. CONCLUSION: HR-PD depicted the SHA, Pcom, AChA, and Acom better than Source-MRA, with the largest differences at the SHA and Pcom. The OA was depicted less well on HR-PD than on Source-MRA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Feasibility of angiographic imaging using fast 3D Magnetic Resonance Spin TomogrAphy in Time-domain (MR-STAT)Magnetic Resonance Materials in Physics Biology and Medicine · 2026
- EXPRESS: Diagnostic Accuracy of Noninvasive Translesional Pressure Ratio Based on Magnetic Resonance Imaging for Intracranial Atherosclerotic Stenosis: A Validation Study.Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2026
- High-Resolution 3T Intracranial Vessel Wall MRI in Patients Evaluated for Suspected Inflammatory Intracranial Vasculopathy: Morphologic and Follow-Up Findings from a Retrospective Case Series.Tomography (Ann Arbor, Mich.) · 2026
- Improved Confidence in the Diagnosis of Intracranial Aneurysmal Lesions Using High-resolution MR Angiography with Deep Learning-based Reconstruction.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2026
- Application of high-resolution magnetic resonance imaging for stroke involving the middle cerebral artery with non-significant stenosisBMC Neurology · 2026
- ArteryX: A Reliable End-To-End Toolbox for Standardized Intracranial Artery Feature Extraction From 3D TOF-MRA.Magnetic resonance in medicine · 2026