Impact of reconstruction-based misalignment correction on image quality, reader agreement, and diagnostic confidence in single-source photon-counting CT.
Kristóf Nagy, Krisztián Kocsis, Gergő Veréb, Sámuel Beke, István Csulak, Réka Sebestény-Dósa, Barnabás Baksa, Miklós Vértes,
Department of Radiology, Medical Imaging Centre, Semmelweis University, 2 Koranyi Sandor Street, Budapest, 1083, Hungary. · Department of Radiology, Medical Imaging Centre, Semmelweis University, 2 Koranyi Sandor Street, Budapest, 1083, Hungary; Heart and Vascular Center, Semmelweis University, 68 Varosmajor Street, Budapest, 1122, Hungary.
Key points
From the paper's conclusion- The correction algorithm reduced misalignment artefacts and enhanced subjective diagnostic confidence on single-source PCD-CT, with benefits observed across readers of varying experience.
Abstract
PURPOSE: Recently, a single-source photon-counting detector (PCD-CT) system with detector settings comparable to the dual-source system has been introduced. Although applicable to coronary CT angiography (CCTA), its lower temporal resolution may lead to more pronounced motion and misalignment artefacts. Image slab misalignment correction algorithm reduces these artefacts; therefore, we aimed to evaluate its effect on subjective image quality metrics on this PCD-CT system. METHODS: CCTA images were reconstructed with and without using misalignment correction algorithm. Four readers with varying experience evaluated coronary vessels using three image quality metrics: motion, misalignment artefact, and diagnostic confidence. Linear mixed-effect models were used to assess the effects of reconstruction type, image quality metrics, vessels, and readers. To assess reader agreement, intraclass correlation and multiple agreement metrics were used. RESULTS: 102 patients (53.9% female) were included in the final analysis. The type of reconstruction significantly affected image quality metric scores (p = 0.031). Post-hoc analysis showed that misalignment corrected reconstruction significantly improved misalignment artefacts (Δ = 0.94, 95% CI, 0.88-0.99, p < 0.01) and diagnostic confidence (Δ = 0.296, 95% CI, 0.24-0.36, p < 0.01). Misalignment correction showed a more modest effect on motion artefacts (Δ = 0.065, 95% CI, 0.008-0.122, p = 0.026). Inter-rater reliability was good for both reconstruction types (ICC = 0.713 and ICC = 0.657 for original dataset and corrected dataset). Agreement with the most experienced reader improved using misalignment correction (Exact agreement with the least experienced reader: 43.3% and 54.1%). CONCLUSION: The correction algorithm reduced misalignment artefacts and enhanced subjective diagnostic confidence on single-source PCD-CT, with benefits observed across readers of varying experience.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Three-dimensional image metric maps for characterizing local image changes associated with AI-based motion correction in coronary CT.Radiological physics and technology · 2026
- Improving image quality by reducing breathing artifacts in CT of patients early after coronary artery bypass graft surgery.The international journal of cardiovascular imaging · 2026
- Photon-counting CT iodine maps for late iodine enhancement: a retrospective feasibility study of image quality and reader confidence.European radiology experimental · 2026
- Optimization of reconstruction strategies for head and neck computed tomography angiography using photon-counting computed tomography: A comparative study with energy-integrating detector computed tomography.European journal of radiology · 2026
- Effect of a motion-correction algorithm on motion-related image quality in mid-diastolic CCTA using 320-detector row CT.Journal of cardiovascular computed tomography · 2026
- Diagnostic performance and clinical impact of photon-counting detector computed tomography in coronary artery disease.Current opinion in cardiology · 2026