Pulmonary embolism in pregnancy and the postpartum period: 16-Year trends in CT pulmonary angiography and lung scintigraphy.
E Kakish, R J Lee, LDe Kock, S Shet, M Feighery, T Derksen, H Atwal, D Kiely,
Department of Radiology, School of Medicine, University College Cork, Cork, Ireland. · Department of Radiology, School of Medicine, University College Cork, Cork, Ireland. Electronic address: 119705019@umail.ucc.ie.
Key points
From the paper's conclusion- Over 16 years, imaging shifted from LS towards CTPA. Diagnostic yield remained low, as expected in a rule-out population, while CTPA was associated with higher maternal effective and breast absorbed doses than LS. These findings underscore the importance of appropriate imaging selection in this population.
Abstract
OBJECTIVES: To evaluate 16-year trends in utilisation, radiation exposure, and diagnostic yield of computed tomography pulmonary angiography (CTPA) and lung scintigraphy (LS) for suspected pulmonary embolism (PE) during pregnancy and postpartum period. MATERIALS AND METHODS: Pregnant and ≤ 6-week postpartum patients undergoing CTPA or LS from 2008 to 2024 were retrospectively studied. CTPA maternal effective, breast absorbed and modelled foetal effective doses were estimated using Monte Carlo modelling. LS maternal effective, breast absorbed and foetal absorbed doses were calculated from administered activity using ICRP coefficients. RESULTS: Of 1,140 imaging examinations, 945 occurred during pregnancy (619 LS; 326 CTPA) and 195 postpartum (33 LS; 162 CTPA). LS comprised 65.5% of pregnancy examinations but 16.9% postpartum compared with 34.5% and 83.1% for CTPA respectively (p < 0.001). CTPA use increased while LS use declined. During pregnancy, PE was detected in 16/619 LS examinations (2.6%) and 12/326 CTPAs (3.7%); postpartum, in 0/33 LS examinations and 11/162 CTPAs (6.8%). Median maternal effective doses during pregnancy were 0.544 mSv for LS (IQR 0.512-0.593, n = 449) and 2.96 mSv for CTPA (IQR 2.23-3.74, n = 305); postpartum effective doses were 1.126 mSv (IQR1.045-1.243, n = 10) and 1.69 mSv (IQR 1.43-2.42, n = 142), respectively. Breast absorbed dose was higher with CTPA during pregnancy and postpartum (both p < 0.001). CONCLUSION: Over 16 years, imaging shifted from LS towards CTPA. Diagnostic yield remained low, as expected in a rule-out population, while CTPA was associated with higher maternal effective and breast absorbed doses than LS. These findings underscore the importance of appropriate imaging selection in this population.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- CT pulmonary angiography in pregnancy and the postpartum period: Diagnostic yield, cardiopulmonary morphometry, and alternative findingsThoracic Radiology · 2026
- Investigation of suspected pulmonary embolus - imaging frequency and diagnostic yield over 10 years in a major UK teaching hospital.Clinical medicine (London, England) · 2026
- Retrospective Assessment of Pulmonary Embolism in Pregnancy and Evaluation of Pregnancy-Adapted YEARS Algorithm.Emergency medicine Australasia : EMA · 2026
- Comparison of three diagnostic strategies for suspicion of pulmonary embolism: planar ventilation/perfusion scan, CT pulmonary angiography and single-photon emission CT ventilation/perfusion scan – a multicentre, non-inferiority randomised controlled trialEuropean Respiratory Journal · 2026
- Evaluating Age-Adjusted D-dimer and Clinical Decision-Making in Suspected Pulmonary Embolism: A Retrospective Clinical Audit and Practitioner Survey.Cureus · 2026
- CT radiation exposure of emergency department patients before, during and after the COVID-19 pandemic.European journal of radiology · 2026