Comparison of signal drop on T2-weighted and post-contrast T1-weighted Dixon MRI in spinal bone marrow lesions.
Yunseong Kim, Hyun Su Kim, Eunju Kim, Young Cheol Yoon, Ji Hyun Lee
Department of Radiology, Samsung Medical Center, School of Medicine, Sungkyunkwan University, Seoul, Republic of Korea. Electronic address: yslovesrad.kim@samsung.com. · Department of Radiology, Samsung Medical Center, School of Medicine, Sungkyunkwan University, Seoul, Republic of Korea; Division of Musculoskeletal Imaging and Intervention, Department of Radiology, University of Washington, Seattle, WA, USA. Electronic address: calmuri@naver.com.
Key points
From the paper's conclusion- GdT1 %drop was significantly lower than T2 %drop with substantially lower specificity, warranting cautious interpretation to avoid misclassification.
Abstract
OBJECTIVE: To compare signal drop percentages between in-phase and out-of-phase images on T2-weighted and post-contrast T1-weighted Dixon MRI in spinal bone marrow lesions and evaluate their diagnostic performance in differentiating benign from malignant lesions. MATERIALS AND METHODS: This retrospective study included patients who underwent post-contrast spine MRI with 3.0 T Dixon sequences between January 2023 and January 2024. Signal drop percentages ([in-phase - out-of-phase] / in-phase) were calculated for T2-weighted Dixon (T2 %drop) and post-contrast T1-weighted Dixon images (GdT1 %drop). T2 %drop and GdT1 %drop were compared using the Wilcoxon signed-rank test. Diagnostic performance was assessed using receiver-operating characteristic analysis with area under the curve (AUC) calculation. Optimal cutoff values were determined to achieve 100 % sensitivity for malignancy while maximizing specificity. Specificities were compared using the McNemar test. RESULTS: Among 78 patients (median age, 63.5 years [interquartile range (IQR), 54.3-70.8]; 37 men, 41 women; 41 benign, 34 malignant, and 3 indeterminate lesions), median T2 %drop and GdT1 %drop were 29.2 % (IQR, 20.3-46.0) and 21.4 % (IQR, 15.4-28.6), respectively. GdT1 %drop was significantly lower than T2 %drop (P < 0.001). The AUC of GdT1 %drop (0.84; 95 % confidence interval [CI], 0.73-0.92) was numerically lower than that of T2 %drop (0.91; 95 % CI, 0.81-0.97), although the difference was not significant (P = 0.132). The specificity of GdT1 %drop was significantly lower than that of T2 %drop at the optimal cutoff values of 27.9 % and 29.0 %, respectively (39.0 % [95 % CI, 24.2-55.5] vs. 80.5 % [95 % CI, 65.1-91.2]; P < 0.001). CONCLUSION: GdT1 %drop was significantly lower than T2 %drop with substantially lower specificity, warranting cautious interpretation to avoid misclassification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- How I Do It: Using the Dixon Method and Fat-Water Imaging in Musculoskeletal MRIRadiology · 2026
- Integrating DWI Parameters with RECIST 1.1 for Early Assessment of Systemic Therapy Response in Lung Cancer Pelvic Bone Metastases.The British journal of radiology · 2026
- Diagnostic value of diffusion-weighted imaging combined with DCE-MRI time-signal intensity curve for differentiating benign from malignant BI-RADS 4 breast lesions.European journal of radiology · 2026
- High-resolution diffusion MRI of rectal cancer ex vivo surgical specimens reveals post-treatment microstructural characteristics of tissue componentsnpj Imaging · 2026
- Apparent diffusion coefficient and intravoxel incoherent motion-derived true diffusion serve as early non-contrast longitudinal biomarkers of neoadjuvant chemotherapy responseScientific Reports · 2026
- Bone tumours with wash-out on dynamic contrast-enhanced MRI: beyond giant cell tumour of bone.Insights into imaging · 2026