Department of Radiology, Samsung Medical Center, School of Medicine, Sungkyunkwan University, Seoul, Republic of Korea. Electronic address: yslovesrad.kim@samsung.com. · Department of Radiology, Samsung Medical Center, School of Medicine, Sungkyunkwan University, Seoul, Republic of Korea; Division of Musculoskeletal Imaging and Intervention, Department of Radiology, University of Washington, Seattle, WA, USA. Electronic address: calmuri@naver.com.

Observational · n=78

Key points

From the paper's conclusion
  • GdT1 %drop was significantly lower than T2 %drop with substantially lower specificity, warranting cautious interpretation to avoid misclassification.

Abstract

OBJECTIVE: To compare signal drop percentages between in-phase and out-of-phase images on T2-weighted and post-contrast T1-weighted Dixon MRI in spinal bone marrow lesions and evaluate their diagnostic performance in differentiating benign from malignant lesions. MATERIALS AND METHODS: This retrospective study included patients who underwent post-contrast spine MRI with 3.0 T Dixon sequences between January 2023 and January 2024. Signal drop percentages ([in-phase - out-of-phase] / in-phase) were calculated for T2-weighted Dixon (T2 %drop) and post-contrast T1-weighted Dixon images (GdT1 %drop). T2 %drop and GdT1 %drop were compared using the Wilcoxon signed-rank test. Diagnostic performance was assessed using receiver-operating characteristic analysis with area under the curve (AUC) calculation. Optimal cutoff values were determined to achieve 100 % sensitivity for malignancy while maximizing specificity. Specificities were compared using the McNemar test. RESULTS: Among 78 patients (median age, 63.5 years [interquartile range (IQR), 54.3-70.8]; 37 men, 41 women; 41 benign, 34 malignant, and 3 indeterminate lesions), median T2 %drop and GdT1 %drop were 29.2 % (IQR, 20.3-46.0) and 21.4 % (IQR, 15.4-28.6), respectively. GdT1 %drop was significantly lower than T2 %drop (P < 0.001). The AUC of GdT1 %drop (0.84; 95 % confidence interval [CI], 0.73-0.92) was numerically lower than that of T2 %drop (0.91; 95 % CI, 0.81-0.97), although the difference was not significant (P = 0.132). The specificity of GdT1 %drop was significantly lower than that of T2 %drop at the optimal cutoff values of 27.9 % and 29.0 %, respectively (39.0 % [95 % CI, 24.2-55.5] vs. 80.5 % [95 % CI, 65.1-91.2]; P < 0.001). CONCLUSION: GdT1 %drop was significantly lower than T2 %drop with substantially lower specificity, warranting cautious interpretation to avoid misclassification.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers