European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences

Combined polymeric and mesoporous carriers for hot-melt extruded resveratrol amorphous solid dispersions: processability, amorphization, and storage stability.

Pia Berglez, Alenka Zvonar Pobirk, Carolina Alva, Ožbej Zupančič, Johannes G Khinast, Marta Počkaj, Rok Dreu, Barbara Sterle Zorec

University of Ljubljana, Faculty of Pharmacy, Aškerčeva cesta 7, 1000 Ljubljana. · Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria.

Key points

From the paper's conclusion
  • Thus, conditions favoring amorphization during HME do not necessarily provide the greatest resistance to recrystallization, highlighting the need to optimize processability and long-term physical stability separately.

Abstract

Resveratrol (RSV) has poor aqueous solubility and a strong tendency to recrystallize, limiting the performance of amorphous solid dispersions (ASDs). This study investigated whether combining polymeric and mesoporous carriers could enable hot-melt extrusion (HME) of physically stable RSV ASDs and how polymer composition, carrier type and content, and RSV loading influenced processability, initial amorphization, and storage stability. Formulations containing PEG 6000, HPMC AS, or Eudragit® EPO, with Syloid® 244 FP or Neusilin® US2, were prepared at RSV loadings of 20-40% (w/w) relative to total polymer mass. Polymers were used either alone or in combination with PEG in ratios 2:1, 1:1, or 1:2. Processable formulations were characterized for RSV content and physical state and re-evaluated after three months under accelerated storage conditions. Mesoporous carriers reduced RSV crystallinity compared to carrier-free PEG systems, while PEG improved extrusion performance. RSV loading was the strongest determinant of crystallinity, with higher loadings producing greater detectable crystallinity after extrusion and after accelerated storage, whereas the formulations showing the g+reatest physical stability contained 20% RSV. Polymer type and polymer-to-PEG ratio showed no significant overall effect on crystallinity after storage. Notably, Neusilin® often promoted superior initial amorphization, yet Neusilin®-containing formulations showed higher crystallinity than corresponding Syloid® formulations after storage. Thus, conditions favoring amorphization during HME do not necessarily provide the greatest resistance to recrystallization, highlighting the need to optimize processability and long-term physical stability separately.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers