European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V

Toward physiologically relevant in vitro release testing of PLGA microspheres for subcutaneous administration.

Giorgia Frigerio, Kate Gridley, Randall J Mrsny, Francesco Cilurzo, Francesca Selmin, Nikoletta Fotaki

Department of Life Sciences, University of Bath, Claverton Down, Bath, Avon BA2 7AY, UK; Department of Pharmaceutical Sciences, University of Milan, via G. Colombo 71, 20133 Milan, Italy. · Department of Life Sciences, University of Bath, Claverton Down, Bath, Avon BA2 7AY, UK.

Preclinical

Key points

From the paper's conclusion
  • These findings indicate that SubQ tissue components may influence PLGA microsphere performances supporting their inclusion in in vitro release methods.

Abstract

Despite nearly 40 years of clinical use, PLGA microspheres (MS) still lack reliable in vitro methods to predict drug release, limiting rational development of new subcutaneous (SubQ) formulations or generics. This study investigated how components of the SubQ environment (e.g. proteins, glycosaminoglycans, and lipids) influence drug release from PLGA microspheres containing flurbiprofen or naltrexone. Four independent SubQ-relevant release media of increasing complexity were designed based on the reported SubQ tissue composition. Drug release was evaluated using the sample-and-separate method and, for the first time with PLGA microspheres, the SubCutaneous Injection Site SimulatOR (SCISSOR) containing different extracellular matrix cartridges. Medium composition affected release in a drug- and formulation-dependent manner. For flurbiprofen-loaded microspheres, differences were mainly confined to the initial burst, with limited effects on the overall release. Naltrexone release from the MS varied markedly among media and was faster and more extensive in albumin-containing media than in electrolyte- containing medium. With the SCISSOR method, flurbiprofen release from the PLGA microspheres was comparable between cartridges, reaching approximately 25% after 7 days, whereas naltrexone release from the microspheres remained below 5% after 4 days. These findings indicate that SubQ tissue components may influence PLGA microsphere performances supporting their inclusion in in vitro release methods.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Toward physiologically relevant in vitro release testing of PLGA microspheres for subcutaneous administration — Science Skim