Inter-reader variability for quality assessment of synthetically degraded prostate MR images aligned with PIQUAL version 2.
Kang-Lung Lee, Jobie Budd, Shu-Huei Shen, Dimitri A Kessler, Chan Kyo Kim, Daniel Margolis, Haytham Shebel, Valdair Francisco Muglia,
Department of Radiology, Taipei Veterans General Hospital, Taipei, 112201, Taiwan; Department of Radiology, University of Cambridge, Cambridge, CB2 0QQ, United Kingdom; School of Medicine, National Yang Ming Chiao Tung University, Taipei, 112304, Taiwan. · Barts Cancer Institute, Queen Mary University of London, London, EC1M 6BQ, United Kingdom; Lucida Medical, Cambridge, CB4 2HY, United Kingdom.
Key points
From the paper's conclusion- Expert radiologists' assessment of image quality is subjective, with inter-reader agreement varying with image quality and type. Higher agreement is demonstrated for extreme MRI examinations of optimal or markedly poor quality, with the greatest disagreement at moderate degradation levels. Diffusion-weighted images, in particular, show more variable assessments, highlighting its susceptibility to noise and artifacts.
Abstract
PURPOSE: The purpose of this study was to evaluate expert radiologists' perceptions of the quality of magnetic resonance imaging (MRI) of the prostate for images that underwent controlled degradation. MATERIALS AND METHODS: Seven-levels of controlled degradations were applied to 10 single-slice image sets, with T2-weighted images degraded using Gaussian noise and blur, and diffusion-weighted images degraded using noise, blur, and elastic deformation. Twelve image sets of varying apparent-diffusion coefficient (ADC)-T2-weighted anatomical mismatch were also included. Ten expert radiologists independently assessed image quality using prostate imaging quality (PI-QUAL) aligned criteria. Inter-reader agreement was evaluated using proportion agreement and Gwet's agreement coefficient 1 (AC1). RESULTS: For T2-weighted images, image quality adequacy declined with increasing noise and blur, with inter-reader agreement highest at minimal and severe degradation (AC1 up to 0.98), and lowest at intermediate levels (AC1 as low as -0.03), demonstrating a U-shaped pattern. For diffusion-weighted imaging, image quality adequacy similarly decreased with increasing blur, and warping, while agreement for noise-degraded images increased from moderate at baseline to substantial at the highest noise levels. ADC- T2-weighted alignment agreement was almost perfect for mismatches < 5 mm (AC1, 0.93), but poor for > 5 mm mismatches (AC1, -0.08). CONCLUSION: Expert radiologists' assessment of image quality is subjective, with inter-reader agreement varying with image quality and type. Higher agreement is demonstrated for extreme MRI examinations of optimal or markedly poor quality, with the greatest disagreement at moderate degradation levels. Diffusion-weighted images, in particular, show more variable assessments, highlighting its susceptibility to noise and artifacts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Image Quality Assessment of Diffusion-Weighted Imaging (DWI) and Its Impact on Apparent Diffusion Coefficient (ADC) as a Quantitative Imaging Biomarker for Predicting Response to Neoadjuvant Chemotherapy in High-Risk Early Breast CancerTomography · 2026
- Improving prostate MRI quality assessment across diverse evaluators and institutional practice through a PI-QUAL v2 lecture: a pilot study.Insights into imaging · 2026
- Diagnostically Calibrated AI Image Quality Framework Applied to Prostate Cancer Detection at MRI.Radiology · 2026
- Evaluation of accelerated whole-body diffusion weighted imaging with deep learning reconstruction in patients with metastatic prostate cancer: assessment of image quality and ADC estimates.medRxiv · 2026
- Protocol optimization for quantitative MRI studies in radiation oncology: II. Diffusion MRIPhysics in Medicine and Biology · 2026
- Deep learning reconstruction and ADC: is quantitative comparability preserved?European journal of radiology · 2026