Cardiac implantable electronic device infection caused by Gordonia terrae: a case report and literature review.
Kanghong Xu, Zhanwei Wang, Feng Ze, Xinyue Liang, Shuo Yang, Yawei Zhang, Hui Wang, Qi Wang
Department of Clinical Laboratory, Peking University People's Hospital, Beijing, China; Department of Clinical Laboratory, Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan, China. · Department of Clinical Laboratory, Peking University People's Hospital, Beijing, China.
Key points
From the paper's conclusion- This case broadens the clinical spectrum of G. terrae infection, highlights the importance of microbiological identification techniques for diagnosing rare device-associated infections, and supports complete device removal combined with individualized antimicrobial therapy.
Abstract
Gordonia terrae is a rare opportunistic pathogen and an uncommon cause of cardiac implantable electronic device (CIED) infection. Herein, we report the first case of CIED infection caused by G. terrae in mainland China and review the literature. A 29-year-old man presented with recurrent skin breakdown, erythema, and sinus tract formation at the pacemaker pocket following device implantation. Culture of pocket tissue yielded G. terrae, which was identified by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) and confirmed by 16S rRNA gene sequencing. The patient underwent complete removal of the pacemaker leads and hardware with pocket debridement, followed by intravenous vancomycin and oral linezolid for a total treatment duration of approximately five weeks. The wound healed without recurrence during follow-up. This case broadens the clinical spectrum of G. terrae infection, highlights the importance of microbiological identification techniques for diagnosing rare device-associated infections, and supports complete device removal combined with individualized antimicrobial therapy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Oritavancin as a Therapeutic Regimen for Cardiac Implantable Electronic Device Infections with Multidrug-Resistant Gram-Positive Cocci: Clinical Case Reports from the ORI-4-CIEDi Study.Antibiotics (Basel, Switzerland) · 2026
- Trends in cardiac implantable electronic device infections: 2015 to 2019BMC Cardiovascular Disorders · 2026
- Campylobacter jejuni as a Rare Pathogen in CIED Pocket Infections: A Case Report and Literature Review.The American journal of case reports · 2026
- Cardiac implantable electronic device infections: Emerging paradigms in precision prevention and personalized management.Trends in cardiovascular medicine · 2026
- Cutaneous warning signs of cardiac implantable electronic device infection: a pictorial guide for clinicians.Frontiers in cardiovascular medicine · 2026
- Abiotrophia defectiva infective endocarditis: a systematic review of published case reports.Frontiers in cardiovascular medicine · 2026