Classical and quantum machine learning with grouped nested feature selection for diabetes and diabetic retinopathy prediction.
Hasibul Hassan Himal, Ekther Jahan
Department of Computer Science and Engineering, Bangladesh University, Dhaka 1207, Bangladesh. Electronic address: hasibul265686@gmail.com. · Department of Computer Science and Engineering, Bangladesh University, Dhaka 1207, Bangladesh. Electronic address: ektherjahan.bu@gmail.com.
Key points
From the paper's conclusion- Classical and quantum/hybrid ROC-AUC values were 0.7597 ± 0.0273 and 0.7322 ± 0.0581 for retinopathy, and 0.9730 ± 0.0182 and 0.8921 ± 0.0418 for early diabetes. Early-diabetes accuracies were 93.78% and 79.24%, respectively. Classical pipelines selected all predictors in every outer fold. All 40 partition checks confirmed zero shared profile groups. Values following ± represent outer-fold sample standard deviations.
Abstract
OBJECTIVE (S): To compare classical classifiers with simulated quantum/hybrid models using training-only feature selection and validation that separates identical predictor profiles. STUDY DESIGN: Two UCI datasets included 1,151 retinopathy and 520 early-diabetes records. Primary validation used stratified grouped five-fold outer and three-fold inner cross-validation without resampling. Groups used complete predictor profiles, excluding labels. Four supervised selectors and all predictors were evaluated with four classical and four quantum/hybrid models. Row-based nested analyses with and without SMOTE provided sensitivity comparisons. RESULTS: Classical and quantum/hybrid ROC-AUC values were 0.7597 ± 0.0273 and 0.7322 ± 0.0581 for retinopathy, and 0.9730 ± 0.0182 and 0.8921 ± 0.0418 for early diabetes. Early-diabetes accuracies were 93.78% and 79.24%, respectively. Classical pipelines selected all predictors in every outer fold. All 40 partition checks confirmed zero shared profile groups. Values following ± represent outer-fold sample standard deviations. CONCLUSION (S): Under tested settings, simulated quantum/hybrid pipelines showed no observed predictive or partial final-evaluation runtime advantage. Grouped validation reduced near-perfect row-based diabetes estimates. Profile grouping does not establish patient-independent or external validation. Undocumented fixed subset-size choices remain a potential source of development bias.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantum vs. Classical Machine Learning for Diabetes Prediction: A Leakage-Controlled Benchmarking Study with Repeated EvaluationComputation · 2026
- Matched but Not Better: An Equivalence-Tested Benchmark of Quantum Machine Learning on Six Clinical Datasets and the QML-Health-READY Reporting FrameworkarXiv · 2026
- Evaluating hybrid quantum-classical learning for financial forecasting: a comparative study with classical machine learning models on BSE indices.Frontiers in artificial intelligence · 2026
- Quantum Kernel Regression and Variational Quantum Regression for the CCS Prediction of Dissolved Organic Matter: A Comparative Benchmarking Study.Journal of the American Society for Mass Spectrometry · 2026
- Benchmarking Quantum Machine Learning for Power-System Attack Detection: Evaluation Choices Can Decide the OutcomearXiv · 2026
- QBioBench: Benchmark of quantum machine learning for peripheral biosignals on real hardwareQuantum Science and Technology · 2026