Incremental value of AI-derived retinal vascular parameters for predicting incident type 2 diabetes.
Xinqing Yang, Sijin Zhou, Xuyang Diao, Menghan Zhu, Yang Pan, Yiwen Dai, Jingya Ma, Yuling Liu,
School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China. · Beijing Airdoc Technology Co., Ltd., Beijing, China; AIM Lab, Faculty of IT, Monash University, Clayton, VIC, Australia; Faculty of Engineering, Monash University, Clayton, VIC, Australia.
Key points
From the paper's conclusion- AI-derived retinal vascular parameters, particularly FDa and atts, provided measurable incremental predictive information beyond ADART for incident T2DM. These findings support the use of retinal AI biomarkers as complementary risk markers, although prospective validation with large sample sizes, recalibration in target populations, and cost-effectiveness assessment are required before clinical use.
Abstract
AIMS: To evaluate whether artificial intelligence (AI)-derived retinal vascular parameters provide incremental predictive value for incident type 2 diabetes (T2DM) beyond the American Diabetes Association Risk Test (ADART), and to assess external performance in an independent Chinese community-based cohort. METHODS: We analysed the UK Biobank (n = 63,968; 70:30 derivation/internal validation split) and the BRAVE cohort (n = 1159; external validation). Multivariable Cox proportional hazards models with/without AI-derived retinal parameters were constructed to predict the risk of incident T2DM. Model performance was assessed using Harrell's C-index with bootstrap confidence intervals, calibration, continuous net reclassification improvement (NRI) with event and non-event components, integrated discrimination improvement (IDI), and decision curve analysis. RESULTS: Retinal arterial fractal dimension (FDa) and arterial tortuosity (atts) were independently associated with incident T2DM after adjustment for ADART. In the UK Biobank internal validation set, adding FDa and atts increased the C-index from 0.746 to 0.751 (delta = 0.005, 95 % CI 0.003 to 0.008); continuous NRI was 0.258, with event NRI 0.158 and non-event NRI 0.100. In BRAVE, the C-index increased from 0.618 to 0.631 (delta = 0.013, 95 % CI 0.009 to 0.016), supporting external validation of discrimination. CONCLUSIONS: AI-derived retinal vascular parameters, particularly FDa and atts, provided measurable incremental predictive information beyond ADART for incident T2DM. These findings support the use of retinal AI biomarkers as complementary risk markers, although prospective validation with large sample sizes, recalibration in target populations, and cost-effectiveness assessment are required before clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cardiometabolic Assessment in Patients with Overweight, Obesity, or Type 2 Diabetes Undergoing Artificial Intelligence-Based Retinal Screening: A Real-World Evidence Study.Metabolic syndrome and related disorders · 2026
- Role of retinal biomarkers in diabetes detection and risk prediction: A systematic scoping reviewDiabetes & Metabolic Syndrome Clinical Research & Reviews · 2026
- Diagnostic Accuracy of Artificial Intelligence-Enabled Retinal Biomarkers for Detecting Type 2 Diabetes and Prediabetes Among Asian Indians [DART Study]Diabetes Technology & Therapeutics · 2026
- Estimated Pulse Wave Velocity Correlates with Indices of Glomerular and Renal Tubular Injury in Individuals with Type 2 Diabetes.Biomedicines · 2026
- Merging artificial intelligence and retinal vascular geometric parameters: A novel tool for diagnosis and prognosis prediction of diabetic nephropathy.Chinese medical journal · 2026
- Retinal Artificial Intelligence Reclassifies SCORE2-Based Cardiovascular Risk Across the ESC/EAS Statin-Indication Boundary: A UK Biobank Prospective Cohort Study.European journal of preventive cardiology · 2026