Clinical radiology

Ultrasound-guided microwave ablation for biopsy-proven breast fibroadenomas ≤3 cm: clinical, imaging, and safety outcomes at 12-month follow-up.

M Yağtu, G Sezgin

Department of Radiology, İzmir Katip Çelebi University Atatürk Training and Research Hospital, İzmir, Türkiye. Electronic address: yagtumehmet@gmail.com. · Department of Radiology, İzmir Egepol Private Hospital, Türkiye.

Observational · n=27

Key points

From the paper's conclusion
  • US-guided MWA provided substantial 12-month reduction in size and volume of biopsy-proven fibroadenomas ≤3 cm with favourable safety and cosmetic outcomes. It may represent a minimally invasive treatment option for appropriately selected symptomatic patients who wish to avoid surgical excision.

Abstract

AIM: The aim of this study was to evaluate the imaging, clinical, and safety outcomes of ultrasound (US)-guided microwave ablation (MWA) for biopsy-proven breast fibroadenomas ≤3.0 cm. MATERIALS AND METHODS: This retrospective study included 27 patients with 27 core-biopsy-proven fibroadenomas ≤3.0 cm treated between January and July 2025. MWA was performed for clinical treatment purposes according to a predefined institutional protocol and was not undertaken as part of a prospective research study. Institutional ethics committee approval was subsequently obtained for retrospective review of the clinical and imaging data. US-guided MWA was performed under local anaesthesia using a 2450-MHz system at 40 W. Clinical and US follow-up was performed at 1, 3, 6, 9, and 12 months. Changes in tumour volume and maximum diameter were evaluated using repeated-measures analysis of variance (ANOVA). RESULTS: The mean MWA duration was 101.3 ± 26.5 s. All 27 procedures were successfully completed. At 12 months, mean maximum tumour diameter decreased from 20.69 ± 6.96 mm to 5.59 ± 1.53 mm, corresponding to a 73.3% reduction. Mean tumour volume decreased from 2.30 ± 1.87 mL to 0.60 ± 0.28 mL, corresponding to a 73.5% reduction (P < .001). Sixteen of 27 lesions achieved >90% volume reduction without residual vascularity on colour Doppler US. No epidermal burns, haematoma, infection, skin depression, or other major adverse events occurred. All patients were satisfied with the cosmetic outcome at 12 months. CONCLUSION: US-guided MWA provided substantial 12-month reduction in size and volume of biopsy-proven fibroadenomas ≤3 cm with favourable safety and cosmetic outcomes. It may represent a minimally invasive treatment option for appropriately selected symptomatic patients who wish to avoid surgical excision.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Ultrasound-guided microwave ablation for biopsy-proven breast fibroadenomas ≤3 cm: clinical, imaging, and safety outcomes at 12-month follow-up — Science Skim