Comparing the Clinical Outcomes of Fractional Flow Reserve and Intravascular Imaging in Guiding Percutaneous Coronary Intervention: A Systematic Review and Meta-analysis.
Sharanya Kaushik, Akshay Machanahalli Balakrishna, Shreya Arvind, Sridhar Mangalesh, Sriram Sunil Kumar, Juan Torrado, Usman Alam, Eleonora Gashi
Jacobi Medical Center, Albert Einstein College of Medicine, 1400 Pelham Parkway South, Bronx, NY 10461, USA. Electronic address: sharanya.kaushik3@gmail.com. · Creighton University School of Medicine, CL and Rachel Werner Center for Health Sciences Education, 2616 Burt Street, Omaha, NE 68178, USA.
Key points
From the paper's conclusion- Among patients with intermediate coronary stenoses, FFR- and IVI-guided strategies were associated with similar clinical outcomes, while FFR guidance reduced PCI utilization.
Abstract
BACKGROUND: Fractional flow reserve (FFR) and intravascular imaging (IVI) are both used to guide management of intermediate coronary stenoses, but comparative outcome data remain limited. METHODS: We systematically searched MEDLINE/PubMed and the Cochrane Central Register of Controlled Trials from inception through September 1, 2025, for randomized controlled trials and comparative observational studies directly comparing physiology-guided versus intravascular imaging-guided strategies for angiographically intermediate coronary stenoses. Outcomes included major adverse cardiovascular events (MACE), all-cause mortality, cardiac mortality, myocardial infarction (MI), target-vessel revascularization (TVR), and PCI rate. Risk ratios (RRs) with 95% confidence intervals (CIs) were pooled using random-effects models. Risk of bias was assessed with RoB 2 for randomized trials and ROBINS-I for observational studies. A sensitivity analysis excluded FLAVOUR II because it used angiography-derived rather than pressure-wire FFR. RESULTS: Six comparative studies including 5,047 participants were included: four randomized trials and two observational studies. No statistically significant differences were detected in all-cause mortality (RR 0.87, 95% CI 0.53-1.42; p=0.58), cardiac mortality (RR 1.11, 95% CI 0.63-1.96; p=0.72), MACE (RR 1.09, 95% CI 0.88-1.35; p=0.42), nonfatal MI (RR 1.45, 95% CI 0.80-2.64; p=0.22), or TVR (RR 1.27, 95% CI 0.85-1.90; p=0.24). Physiology guidance was associated with lower PCI utilization (RR 0.60, 95% CI 0.48-0.75; p<0.001), with substantial heterogeneity (I²=93.6%). Exclusion of FLAVOUR II did not materially alter the findings, including PCI utilization (RR 0.55, 95% CI 0.45-0.67; I²=76.7%). CONCLUSIONS: Among patients with intermediate coronary stenoses, FFR- and IVI-guided strategies were associated with similar clinical outcomes, while FFR guidance reduced PCI utilization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intravascular Imaging-Guided Drug-Eluting Stenting for Complex Coronary Lesions: A Meta-Analysis of Randomized Controlled Trials.JACC. Advances · 2026
- Intravascular imaging guidance in complex PCI: a meta-analysis of randomized trials across complex lesion subsets.International journal of cardiology · 2026
- Clinical outcomes of angiography-derived fractional flow reserve compared with invasive and imaging-guided PCI: a network meta-analysisEuropean Heart Journal · 2026
- Intravascular Imaging-Guided Percutaneous Coronary Intervention for Calcified Coronary Lesions: A Network Meta-Analysis.JACC. Advances · 2026
- Intravascular imaging-guided percutaneous coronary intervention versus angiography guidance: updated meta-analysis of randomised trialsEuropean Heart Journal · 2026