Colloids and surfaces. B, Biointerfaces

Surface enhanced Raman scattering and upconversion luminescence dual mode magnetic sandwich immunoassay based on β-NaGdF4:Yb,Er nanoparticles and Au nanobipyramids for sensitive detection of p-tau217.

Wenqi Liu, Lu Xing, Junyu Chen, Yasheng Dai, Mingrui Song, Shiyuan Wang, Changgan Lai, Tao Jiang,

Department of Radiology, The First Affiliated Hospital of Ningbo University, Ningbo, Zhejiang 315010, China. · School of New Energy, Ningbo University of Technology, Ningbo, Zhejiang 315211, China.

Key points

From the paper's conclusion
  • In this study, a dual-mode magnetic sandwich immunoassay platform combining surface-enhanced Raman scattering (SERS) and upconversion luminescence (UCL) was developed for sensitive detection of p-tau217.

Abstract

Plasma phosphorylated tau 217 (p-tau217) is widely recognized as a promising biomarker for early Alzheimer's disease (AD) diagnosis. However, it is still highly desirable to achieve preliminary and reliable qualitative as well as quantitative detection of p-tau217. In this study, a dual-mode magnetic sandwich immunoassay platform combining surface-enhanced Raman scattering (SERS) and upconversion luminescence (UCL) was developed for sensitive detection of p-tau217. The platform was constructed using magnetic β-NaGdF4:Yb,Er nanoparticles (NPs) and anisotropic Au nanobipyramids (NBPs). To achieve ultrasensitive SERS detection of p-tau217, anisotropic Au NBPs with abundant plasmonic hotspots were employed as Raman immunoprobes, leading to a pronounced enhancement factor of 8.02 × 107. In parallel, paramagnetic β-NaGdF4:Yb,Er NPs exhibiting strong green UCL emission enabled efficient magnetic separation and direct visual readout of target molecules. Notably, the localized surface plasmon resonance effect of Au NBPs further induced a significant enhancement of the UCL emission of β-NaGdF4:Yb,Er NPs. Based on the developed dual-mode platform, specific recognition of p-tau217 in human plasma samples was successfully achieved. The UCL mode enabled direct visual readout and quantitative analysis with a limit of detection (LOD) of 2.49 pg/mL. More importantly, the SERS mode further enabled ultrasensitive quantitative detection with a remarkably low LOD of 0.33 pg/mL. Specifically, the proposed dual-mode strategy is of great importance for reliable detection of AD-related biomarkers and is expected to support future applications in early disease screening.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers