Colloids and surfaces. B, Biointerfaces

Gallic acid carbon dot-supported heparin-like polymer as an optimized membrane-anchored anticoagulant for functionalization of hemodialysis membranes.

Yi Wang, Teng Xiao, Meijiao Wu, Qiang Zhao, Jianhua Zhou, Yu Zhang

Department of Pediatrics,Tongji Hospital, Tongji Medical College, Huazhong University of Science andTechnology, Wuhan, 430030, PR China. · Key Laboratory of Material Chemistry for Energy Conversion and Storage (Ministry of Education), School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan, 430074, PR China.

Key points

From the paper's conclusion
  • Collectively, these findings highlight the translational promise of this rationally designed dual-action hemodialysis membrane, where localized durable ROS scavenging and surface-confined anticoagulation operate in concert to mitigate key pathophysiological drivers of dialysis-associated complications.

Abstract

Conventional hemodialysis membranes exhibit suboptimal blood compatibility, predisposing patients to thrombotic events and oxidative stress-associated complications that accelerate disease progression. To address this challenge, we developed a gallic acid carbon dots (GA-CDs)-functionalized polyethersulfone (PES) membrane via polydopamine-assisted co-deposition of nitrogen-doped GA-CDs and a heparin-mimetic polymer. The resulting membrane features stable surface immobilization of GA-CDs, conferring durable hemocompatibility and intrinsic dual functionality: (i) sustained ROS-scavenging-driven antioxidant activity for long-term oxidative stress mitigation; and (ii) enhancement of anticoagulant performance through suppression of oxidative stress-mediated tissue factor (TF) activation, thereby synergistically preventing thrombosis. Mechanistically, GA-CDs activated the nuclear factor erythroid 2-related factor 2 (Nrf2) signaling cascade to upregulate endogenous antioxidant enzymes, efficient reactive oxygen species (ROS) clearance, and protection against oxidative cellular damage. Concurrently, by scavenging ROS, GA-CDs suppressed oxidative stress-induced tissue factor activation, establishing a functional link between redox homeostasis and coagulation regulation. In vitro evaluation demonstrated outstanding dual functionality: potent free radical scavenging capacity (83% DPPH and 97% ABTS⁺ scavenging), significantly prolonged activated partial thromboplastin time (APTT 420 s, 8.4-fold increase vs. control), excellent cytocompatibility, and markedly improved hemocompatibility. Collectively, these findings highlight the translational promise of this rationally designed dual-action hemodialysis membrane, where localized durable ROS scavenging and surface-confined anticoagulation operate in concert to mitigate key pathophysiological drivers of dialysis-associated complications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers