Normative data of laser evoked potentials using Nd:YAP laser.
Egle Sukockiene, Caroline Perchet, Christelle Créac'h, Luis Garcia-Larrea, Agustina M Lascano
Division of Neurology, Department of Clinical Neuroscience, Geneva University Hospitals and University of Geneva, Faculty of Medicine, Geneva, Switzerland. · Central Integration of Pain (NeuroPain) Lab-Lyon Neuroscience Research Centre, INSERM U1028, CNRS, UMR5292, Université Claude Bernard, Bron, France.
Key points
From the paper's conclusion- This study provides the most comprehensive Nd:YAP LEP normative dataset to date, including distal and proximal sites and spot-size-specific reference limits.
Abstract
OBJECTIVES: To establish a robust multi-centre normative database for Nd:YAP laser-evoked potentials (LEPs) across distal and proximal stimulation sites, and to quantify the impact of laser spot size (energy density) and demographic factors on LEP parameters. METHODS: One hundred nine healthy adults (57 females) were recruited from three centres (Geneva, Lyon, Saint-Etienne). Nd:YAP laser pulses were delivered with a 3-mm beam (Centre 1) or 4-mm beam (Centres 2-3). LEPs were recorded from standard EEG sites (including Fz/Cz/Pz and contralateral temporal leads). Stimulation sites included hand dorsum (n = 109), foot dorsum (n = 80), thigh and upper neck (both n = 43). N1, N2, and P2 latencies and amplitudes were measured and normal limits estimated as mean ± 99.9% confidence interval. ANCOVA (age-corrected) tested spot-size effects; repeated-measures ANOVA tested site effects; correlations assessed age/height associations. RESULTS: The vertex N2-P2 complex was consistently recorded across centres and sites (100% for hand, thigh, neck; ∼97% for foot). N1 detection was less consistent, particularly with larger spot size and at the foot. Smaller spot size (higher energy density) yielded shorter N2/P2 latencies and larger N2-P2 amplitudes for hand stimulation, and shorter P2 latency for foot stimulation. Sex and height showed no significant effects. Increasing age was associated with longer N2/P2 latencies and reduced N2-P2 amplitudes for distal sites, with minimal age effects at proximal sites. CONCLUSIONS: This study provides the most comprehensive Nd:YAP LEP normative dataset to date, including distal and proximal sites and spot-size-specific reference limits. SIGNIFICANCE: These data support standardized, high-specificity clinical interpretation of LEPs for assessing small-fibre and spinothalamic pathway dysfunction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- From normative values to pain assessment models: A large-scale study of laser-evoked brain responses.NeuroImage · 2026
- Effectiveness of GV20-based wearable low-level laser acupoint therapy for pain on headLasers in Medical Science · 2026
- Clinical applications of localized vibration for pain relief.European journal of physical and rehabilitation medicine · 2026
- Spot size variation and skin interaction of long-pulse 1064nm Nd: YAG laser used for varicose veins treatment: A prospective, randomized, assessor-blinded ex vivo study.Phlebology · 2026
- Low-energy laser peening induces surface microtopography and enhances early osteoblastic cell attachment on commercially pure titaniumDiscover Applied Sciences · 2026
- The Effect of Different Auditory Conditions on Pattern-Reversal Visual Evoked Potentials (PVEPs) in Healthy Adults.Brain sciences · 2026