Computer methods and programs in biomedicine

Accuracy improvement of 3D hepatic vascular network in ultrasound volumes by incorporating multi-module learning of vessel radius patterns and bifurcation likelihood distribution into 3D U-net.

Yukino Takahashi, Kaori Shinoda, Takumi Noda, Kaho Takahashi, Takeru Kurihara, Shinya Onogi, Yoshikazu Nakajima, Yoshihiro Edamoto,

Tokyo Univ. of Agri. and Tech, Japan. · Institute of Science Tokyo, Japan.

Key points

From the paper's conclusion
  • The model incorporating vessel radius and bifurcation information increased the Recall of both veins, suggesting improved extraction of thin vessels and bifurcation regions, at the cost of lower Precision. A proof-of-concept registration experiment further suggested its potential to contribute to more accurate 2D-3D registration, although validation with patient data remains as future work.

Abstract

BACKGROUND AND OBJECTIVE: In our previous work, although we extracted the vascular volume from preoperative ultrasound volume using 3D U-Net, discontinuities remained in thin vessels and bifurcation regions. To address this issue, this study newly introduced a multi-module learning framework capable of learning local structural features such as vessel radius and bifurcation regions. METHODS: The first module was established considering vessel radius to promote the learning of thin vessels. The second and third modules, which reflect vascular centerlines and bifurcation likelihood distribution, respectively, were introduced to enhance learning connectivity in thin vessels and bifurcation areas. We prepared eight training models by combining those modules, plus a 3D U-Net baseline, and compared them using Wilcoxon signed-rank tests with Holm adjustment. RESULTS: Compared with the 3D U-Net, Model VII (first and third modules) improved the portal vein Dice coefficient and the Recall of both veins. Compared with the conventional method (Model I), it increased the Recall of both veins, whereas the Dice improvements (12.6% portal vein, 2.9% hepatic vein) were not significant after adjustment. In proof-of-concept registration using simulated 2D planes from six subjects, the RMS decreased by 30.2%. CONCLUSIONS: The model incorporating vessel radius and bifurcation information increased the Recall of both veins, suggesting improved extraction of thin vessels and bifurcation regions, at the cost of lower Precision. A proof-of-concept registration experiment further suggested its potential to contribute to more accurate 2D-3D registration, although validation with patient data remains as future work.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Accuracy improvement of 3D hepatic vascular network in ultrasound volumes by incorporating multi-module learning of vessel radius patterns and bifurcation likelihood distribution into 3D U-net — Science Skim