Morphometry-based detection of deep learning faults in glomerular segmentation.
Hrafn Weishaupt, Justinas Besusparis, Nazanin Mola, Ståle Sund, Sabine Leh
Department of Pathology, Haukeland University Hospital, Bergen, 5021, Norway; Department of Clinical Medicine, University of Bergen, Bergen, 5021, Norway. Electronic address: hrafn.holger.weishaupt@helse-bergen.no. · Department of Pathology, Haukeland University Hospital, Bergen, 5021, Norway.
Key points
From the paper's conclusion- In summary, the work demonstrates the methodological aspects and benefits of shape analysis for evaluating glomerular segmentation results. We are convinced that, by applying such a strategy for detecting segmentation errors, it will be possible to approach a more time-efficient correction of deep learning-derived glomerular annotations.
Abstract
BACKGROUND AND OBJECTIVE: Deep learning-based segmentation has evolved to a powerful strategy for automatically annotating glomeruli in kidney biopsy images. However, since any artificial intelligence can make mistakes, strategies for identifying and correcting faulty annotations are often indispensable. Yet, how can such a validation be achieved without the laborious task of a pathologist manually checking every single image? To address this issue, the current project performed an extensive study on the use of shape analysis to automatically evaluate the glomerular annotations produced by deep-learning segmentation. METHODS: A large repertoire of over 30 shape descriptors was applied to over 170000 glomerular predictions, utilizing both qualitative and quantitative evaluations, including enrichment analyses of human-labeled segmentation faults. RESULTS: The study found that morphometry could successfully highlight and distinguish between three different types of segmentation inconsistencies. In addition, using shape descriptors to rank segmentation annotations, it was possible to obtain a distinct enrichment of errors on the leading edge of the ranking, implying that pathologists would only have to inspect and correct the most suspicious fraction of all annotations. Ultimately, the study suggested a panel of three shape descriptors that enabled an efficient enrichment of all errors, respective or irrespective of error type. CONCLUSIONS: In summary, the work demonstrates the methodological aspects and benefits of shape analysis for evaluating glomerular segmentation results. We are convinced that, by applying such a strategy for detecting segmentation errors, it will be possible to approach a more time-efficient correction of deep learning-derived glomerular annotations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A review of deep learning applications on histopathologic and genomic data in focal segmental glomerulosclerosis.Computational biology and chemistry · 2026
- Development of a deep learning model for glomerulus detection and segmentation in kidney histopathology imagesmedRxiv · 2026
- How Close Are We? Limitations and Progress of AI Models in Banff Lesion Scoring.Proceedings of SPIE--the International Society for Optical Engineering · 2026
- Clinical application of deep learning-based measurement of glomerular morphometry in IgAN.Frontiers in immunology · 2026
- The APL Doesn't Fall Far From The Tree: Unsupervised Artefact Prototype Learning in HistopathologyarXiv · 2026
- Interpretable Multiple-Instance Learning of Glomerular Pathomics and Subtype Ratios for eGFR ClassificationarXiv · 2026