Short interval intracortical facilitation: comparison between threshold-tracking and conventional amplitude recording methods.
Hatice Tankisi, Ellen Myrskog, Hossein Pia, Gaia Fanella, Jose Manuel Matamala, Lucia Del Valle, Benjamin Bardel, H Evren Boran,
Department of Clinical Neurophysiology, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark. · Department of Clinical Neurophysiology, Aarhus University Hospital, Aarhus, Denmark.
Key points
From the paper's conclusion- Divergence of T-SICF-1 from A-SICF was attributed to the weaker test stimuli, stronger conditioning stimuli, and contamination by short-interval intracortical inhibition, so that unlike A-SICF and T-SICF-2, T-SICF-1 cannot be regarded as a good indicator of I-wave facilitation.
Abstract
OBJECTIVE: Among the cortical excitability measurements performed by transcranial magnetic stimulation, short-interval intracortical facilitation (SICF) is of clinical interest as a potential biomarker for cortical dysfunction in disorders such as Parkinson's disease. This study was undertaken to compare conventional amplitude measurements (A-SICF) with a published threshold-tracking alternative (T-SICF-1). METHODS: A-SICF was measured as the increase in motor evoked potential (MEP) amplitude when a stimulus that evoked a 1 mV MEP was followed by a subthreshold conditioning stimulus. For T-SICF-1, facilitation was measured as the decrease in threshold for a 200 µV MEP when followed by a conditioning stimulus 95% of that threshold. A-SICF and T-SICF-1 were both recorded twice from 60 healthy volunteers, using 10 stimuli at each of 14 inter-stimulus intervals (ISI) from 1 to 4.9 ms. Twenty of the subjects were later tested with a new threshold-tracking protocol (T-SICF-2), with stimuli the same as A-SICF when there was no facilitation. RESULTS: T-SICF-1 values were less variable than normalized A-SICF ones, but correlation between them over the range of ISIs was poor (R = -0.586). T-SICF-1 showed appreciable facilitation when A-SICF showed none. Correlation between T-SICF-2 and normalized A-SICF was much stronger (R = -0.896), but variability was no better. CONCLUSIONS: Divergence of T-SICF-1 from A-SICF was attributed to the weaker test stimuli, stronger conditioning stimuli, and contamination by short-interval intracortical inhibition, so that unlike A-SICF and T-SICF-2, T-SICF-1 cannot be regarded as a good indicator of I-wave facilitation. SIGNIFICANCE: T-SICF-1 is not recommended as an alternative to A-SICF.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Immediate transcranial magnetic stimulation-evoked potentials reveal short-latency intracortical inhibition.The Journal of physiology · 2026
- Stimulus predictability rather than inter-trial interval itself affects motor evoked potential amplitudesbioRxiv · 2026
- Repetitive suprathreshold paired-pulse transcranial magnetic stimulation alters corticospinal excitabilitybioRxiv · 2026
- The effects of TMS stimulus direction on corticospinal and cortico-cortical excitability of the lower limb in healthy adults.Physiological reports · 2026
- Paired-Pulse TMS as a Window into Cortical Microcircuits: Mechanistic Insights and Translational Challenges.Biomolecules · 2026
- Intra- and Inter-Session Reliability of Average- and Trial-Level Motor Evoked Potential Amplitudes.Brain sciences · 2026