Comparative incidence and severity of iodinated and gadolinium-based contrast reactions using actual administration counts: A five-year single-center study.
Sung-Il Kang, Chung-Hwan Kang, Kyung-Bae Lee
Department of Radiology, Konkuk University Medical Center, Seoul, 05030, Republic of Korea. · Department of Radiology, Konkuk University Medical Center, Seoul, 05030, Republic of Korea. Electronic address: chkang@kuh.ac.kr.
Key points
From the paper's conclusion- ICM showed a higher incidence of reported reactions than GBCAs, but severe reaction rates per administration were similar. Prior ICM reaction history may inform GBCA risk assessment; integrated cross-modality screening requires further validation.
Abstract
PURPOSE: This study compared the incidence, severity, and factors associated with adverse reaction severity for iodinated contrast media (ICM) and gadolinium-based contrast agents (GBCAs) using actual administration counts. METHODS: We retrospectively reviewed 849 ICM-related and 193 GBCA-related adverse reaction reports from 2021 to 2025. Denominators were 204,579 contrast-enhanced CT and 66,233 MRI examinations actually performed, excluding angiographic and interventional use. Reaction severity was classified according to American College of Radiology criteria; onset was categorized as immediate or delayed. RESULTS: Adverse reaction incidence was higher with ICM than GBCAs (0.415% vs. 0.291%; odds ratio 1.426, p < 0.001). Iopamidol and gadobutrol had the highest incidence within their respective classes. Among patients with reactions, moderate-to-severe reactions were more frequent with ICM (22.1% vs. 10.9%), whereas severe reaction rates per 10,000 administrations were similar (0.73 vs. 0.91; p = 0.618). Previous reaction history was associated with greater severity among those with reactions. Eleven patients had reactions to both contrast classes, including seven on the same day. Agent-specific comparisons require cautious interpretation owing to potential confounding. CONCLUSION: ICM showed a higher incidence of reported reactions than GBCAs, but severe reaction rates per administration were similar. Prior ICM reaction history may inform GBCA risk assessment; integrated cross-modality screening requires further validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Costs and imaging delays associated with acute reactions to contrast material: A single-center retrospective study.Journal of the American College of Radiology : JACR · 2026
- Adverse and hypersensitivity reactions after intravascular administration of nonionic iodine-based contrast media: Do agent-specific differences inform contrast agent selection?European Radiology Abdomen · 2026
- A disproportionality analysis of differences in hypersensitivity reactions to iodinated contrast media using the FDA adverse event reporting system (FAERS).International journal of clinical pharmacology and therapeutics · 2026
- Hypersensitivity to iodine-containing contrast media: myths and realitiesInfusion & Chemotherapy · 2026
- Real-world evidence on gadoteridol safety: A 20-year FAERS database study revealing critical adverse reaction patterns.Medicine · 2026
- Safety Profiles of Ionic and Non-Ionic Contrast Agents Used in Percutaneous Coronary Intervention: Analysis of FAERS Data : Short title: Safety Profiles of Ionic and Non-Ionic Contrast Agents Used in Percutaneous Coronary Intervention.Galen medical journal · 2026