Static plantar pressure measurements do not predict high-pressure regions during shod walking in diabetic subjects.
Dylan Heino, Scott Telfer, William R Ledoux, Brittney C Muir
VA RRDT Center for Limb Loss and MoBility (CLiMB), VA Puget Sound Health Care System, 1660 S Columbian Way, MS 151, Seattle, WA 98108, United States; Department of Mechanical Engineering, University of Washington, 3900 E Stevens Way NE, Box 352600, Seattle, WA 98195, United States. Electronic address: dheino13@uw.edu. · VA RRDT Center for Limb Loss and MoBility (CLiMB), VA Puget Sound Health Care System, 1660 S Columbian Way, MS 151, Seattle, WA 98108, United States; Department of Mechanical Engineering, University of Washington, 3900 E Stevens Way NE, Box 352600, Seattle, WA 98195, United States; Department of Orthopaedic Surgery and Sports Medicine, University of Washington, 1959 NE Pacific St., Box 356500, Seattle, WA 98195, United States. Electronic address: telfers@uw.edu.
Key points
From the paper's conclusion- Static pressure measurements demonstrated an association with dynamic plantar pressure but limited spatial agreement with predicting dynamic high-pressure regions. Static measurements may provide information about dynamic high-pressure regions but should not replace dynamic in-shoe pressure assessment for targeted offloading of insoles.
Abstract
BACKGROUND: Foot ulceration is a serious complication of diabetes and associated with elevated plantar pressures during walking. Custom accommodative insoles are most effective when informed by dynamic pressure data; however, static pressure collection offers a faster and more clinically feasible alternative. The ability of static pressure measurements to predict dynamic high-pressure regions remains unclear and needs investigation. METHODS: Static in-shoe and static barefoot plantar pressure measurements were compared with dynamic in-shoe pressure data from 31 feet in 18 participants with elevated dynamic in-shoe forefoot pressures. Dynamic high-pressure regions were defined as sensors exceeding 200 kPa. Peak plantar pressure at dynamic high-pressure regions and sensor-level Pearson and Spearman correlations were compared between static and dynamic measurements. Receiver operating characteristic curves were used to determine static pressure thresholds for identifying dynamic high-pressure regions. Dice coefficient, sensitivity, and positive predictive value assessed spatial agreement and classification performance. FINDINGS: Static peak plantar pressure at dynamic high-pressure regions and sensor-level correlations were higher for static in-shoe than static barefoot comparisons (p < 0.001). Static pressure thresholds were 40.4 kPa for in-shoe and 55.8 kPa for barefoot data, with AUCs of 0.85 and 0.72, respectively. Dice coefficients were 0.31 and 0.27, sensitivity was 0.80 and 0.66, and positive predictive values were 0.22 and 0.19 for static in-shoe and barefoot data. INTERPRETATION: Static pressure measurements demonstrated an association with dynamic plantar pressure but limited spatial agreement with predicting dynamic high-pressure regions. Static measurements may provide information about dynamic high-pressure regions but should not replace dynamic in-shoe pressure assessment for targeted offloading of insoles.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical Foot Findings and Plantar Pressure Assessment in Type 2 Diabetes: A Cross-Sectional Comparison of Static and Dynamic MeasuresExperimental and Applied Biomedical Research (EABR) · 2026
- Improving offloading in diabetic feet: 3D-printed custom accommodative insoles outperform standard of care.PloS one · 2026
- Design and evaluation of a custom contoured pneumatic insole for active plantar pressure offloading.Journal of rehabilitation and assistive technologies engineering · 2026
- Clinical Reference Values for Dynamic Plantar Pressure Assessment in Healthy Young Adults: Sex Differences and Bilateral Symmetry.Life (Basel, Switzerland) · 2026
- Immediate Effects of Dynamic and Rigid Taping on Static and Dynamic Plantar Pressure Distribution in Individuals with Hallux Valgus: A Cross-Over Study.Journal of clinical medicine · 2026
- A framework for robust spatiotemporal analysis of dynamic plantar pressure measurement over the stance phase of gait.Journal of biomechanics · 2026