A chairside multimodal platform for temporomandibular joint biomechanical data acquisition: Technical evaluation and illustrative analysis.
Shuchun Sun, Brooke Damon, Jichao Zhao, Konstantinia Almpani, Rachel Chung, Priyam Jani, Jonathan Mei, Ishaan Mehrotra,
Clemson-MUSC Joint Bioengineering Program, Department of Bioengineering, Clemson University, Clemson, SC 29634, United States of America; Department of Oral Health Sciences, Medical University of South Carolina, Charleston, SC 29425, United States of America. · Clemson-MUSC Joint Bioengineering Program, Department of Bioengineering, Clemson University, Clemson, SC 29634, United States of America.
Key points
From the paper's conclusion- The platform enabled chairside acquisition of multimodal biomechanical data for subsequent offline analysis. This platform could support subject-specific biomechanical analysis and future clinical studies of TMJ function.
Abstract
BACKGROUND: Temporomandibular joint (TMJ) biomechanics can be characterized by mandibular motion, masticatory muscle activity, and bite force generation. These measurements can provide functional inputs for subject-specific computational analyses of internal joint mechanics. However, existing tools typically measure these signals using separate hardware and software platforms, complicating their combined acquisition at chairside. METHODS: We developed and technically evaluated a multimodal platform for chairside acquisition of TMJ biomechanical data. The platform integrates motion, bite force, muscle activity, acoustic, and event-timing measurements with software for real-time preview, protocol guidance, and synchronized export. Technical evaluation included rigid-bar tracking tests, spectacle-frame stability testing during jaw tasks, and static force-sensor linearity testing. We analyzed pre- and postoperative data from an orthognathic surgery patient using offline kinematic, force-control, and computational modeling workflows. FINDINGS: Rigid-bar tracking tests yielded mean length deviations of 0.03 mm under static conditions and mean RMSE of 0.16 mm during movement. Spectacle-to-maxillary RMS translational and rotational differences were 0.28 ± 0.04 mm and 0.06° (SD < 0.01°) during maximum mouth opening-closing, and 0.30 ± 0.09 mm and 0.13 ± 0.03° during dynamic biting. Linear regression of force-sensor measurements against applied loads of 0-50 N yielded R2 = 0.998. In the illustrative case, platform setup took approximately 15 min, followed by approximately 15 min of chairside data acquisition. Offline analysis yielded pre- and postoperative mandibular kinematic measurements, bite-force tracking deviations, and model-estimated TMJ disc stresses. INTERPRETATION: The platform enabled chairside acquisition of multimodal biomechanical data for subsequent offline analysis. This platform could support subject-specific biomechanical analysis and future clinical studies of TMJ function.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pilot validation of a piezo‑resistive gnathodynamometer for maximum voluntary bite force measurement in adults: a cross sectional comparative study.BMC oral health · 2026
- Comparison and Inter-System Agreement of Three Digital Jaw-Tracking Systems: A Comparative Within-Subject Study.Dentistry journal · 2026
- Technological Evolution and Clinical Applications of Jaw Motion Tracking: A Scoping Review.Journal of dentistry · 2026
- Biomechanical Evaluation of the Temporomandibular Joint Following Multi-Directional Orthognathic Surgery: A Finite Element Analysis.Medical engineering & physics · 2026
- Towards minimally invasive prosthetic surgery of the temporomandibular joint: design and integrated CAD-FEM preclinical approach on the mini-pig.Computer methods in biomechanics and biomedical engineering · 2026
- Dental Occlusion Measurement: A Methodological Evaluation to Improve Clinical Gnathology.Sensors (Basel, Switzerland) · 2026