Can velocity increment derived from a single, lumbar-mounted inertial measurement unit serve as a surrogate for propulsion force impulse in healthy and post-stroke individuals?
Lars van Rengs, Katrijn Smulders, Brenda E Groen, Noël L W Keijsers
Department of Research, Sint Maartenskliniek, Nijmegen, the Netherlands; Department of Sensorimotor Neuroscience, Donders Institute for Brain, Cognition and Behavior, Radboud University, Nijmegen, the Netherlands. Electronic address: l.vanrengs@maartenskliniek.nl. · Department of Research, Sint Maartenskliniek, Nijmegen, the Netherlands.
Key points
From the paper's conclusion- Lumbar anterior velocity increment showed poor validity for estimating propulsion force impulse in both healthy and post-stroke individuals, suggesting that a single, lumbar-mounted IMU is insufficient for accurate assessment of propulsion force.
Abstract
BACKGROUND: Paretic propulsion is challenging to measure outside the laboratory. Trunk anterior acceleration reflects late-stance velocity increment, potentially corresponding to the net propulsion force generated by the legs. We evaluated whether anterior velocity increment from a lumbar-mounted inertial measurement unit (IMU) can serve as a surrogate for propulsion force impulse in healthy and post-stroke individuals. METHODS: Seventeen healthy and thirteen post-stroke individuals completed a 2-min self-paced treadmill walking trial. Step-by-step anterior velocity increments were derived from lumbar IMU acceleration and compared with propulsion force impulses obtained from treadmill-embedded force plates. Group-level and individual-level associations (R2) between lumbar velocity increment and propulsion force impulse, and root mean squared errors (RMSE) were calculated using linear mixed models. To test whether step aggregation improves validity, we compared individual-level R2 and RMSE across 1-, 3-, and 5-step conditions using Friedman tests. FINDINGS: Group-level associations were significant but weak (marginal R2: healthy = 0.32; paretic leg = 0.15; non-paretic leg = 0.05), with corresponding RMSE values of 0.061, 0.073, and 0.064 N·s/kg. Median [IQR] individual-level R2 was 0.42 [0.34-0.48] for healthy individuals, 0.19 [0.02-0.52] for the paretic leg, and 0.03 [0.02-0.25] for the non-paretic leg, and RMSE values were 0.022 [0.020-0.025], 0.030 [0.023-0.035], 0.038 [0.027-0.042], respectively. Step aggregation did not affect R2 but significantly reduced RMSE. INTERPRETATION: Lumbar anterior velocity increment showed poor validity for estimating propulsion force impulse in both healthy and post-stroke individuals, suggesting that a single, lumbar-mounted IMU is insufficient for accurate assessment of propulsion force.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Beyond Walking Speed: Estimating and Classifying Post-Stroke Gait Propulsion From Standardized Clinical Measures.medRxiv : the preprint server for health sciences · 2026
- In-Field IMU-Based Monitoring of Running-Specific Prostheses and Athlete Movement During Long-Distance Running: A Case StudyApplied Sciences · 2026
- Assessment of IMU-derived lower-limb kinematics in transtibial amputees: A practical and accessible clinical workflow.PloS one · 2026
- Reliability and Validity of Lumbar-Mounted IMU for Postural Sway Assessment in Healthy Adults.Sensors (Basel, Switzerland) · 2026
- Monitoring of Upper-Limb Functional Movements After Stroke: Optimizing Threshold-Based Detection With Inertial Measurement Units.IEEE open journal of engineering in medicine and biology · 2026
- In-field temporal phase analysis of running: performance assessment of 36 IMU-based algorithms across different device positions and running speeds.Journal of biomechanics · 2026