Assessing the Impact of 89Zr-Girentuximab PET/CT on Stated Management Preferences: Results from an Exploratory Survey of Urologic Oncologists.
Gianpaolo P Carpinito, Apoorv Dhir, Steven P Rowe, Hung-Jui Tan, Mary E Westerman, Zachary S Feuer, Matthew C Raynor, Alexander P Kenigsberg,
Department of Urology, University of North Carolina, Chapel Hill, NC, 27599; Department of Urology, Boston University School of Medicine, Boston, MA, 02118. · Department of Urology, University of North Carolina, Chapel Hill, NC, 27599.
Key points
From the paper's conclusion- PET-avid 89Zr-girentuximab results significantly influenced hypothetical decision-making in a variety of ccRCC scenarios. Most notably, PET-avid results reduced rates of responses favoring biopsy. Non-PET-avid results impacted response distribution in a majority of vignettes but often shifted management toward additional diagnostic work-up. These results highlight the need for future exploration of the application of the 89Zr-girentuximab PET/CT in clinical practice.
Abstract
BACKGROUND: 89Zr-girentuximab carbonic anhydrase IX (CAIX)-targeted PET/CT is a novel molecular imaging modality capable of accurately identifying and staging clear cell renal cell carcinoma (ccRCC). In this exploratory study, we employed carefully constructed case vignettes in a survey of urologic oncologists to gain hypothesis-generating insights surrounding potential applications. MATERIALS AND METHODS: A 9-item, vignette-based survey was developed, pretested, and distributed by the Society of Urologic Oncology (SUO). For each vignette, respondents rated likelihood of pursuing specific management strategies on a 5-point Likert scale under 3 imaging conditions: (1) standard imaging (SI), (2) SI with PET-avid 89Zr-girentuximab scan, and (3) SI with non-PET-avid 89Zr-girentuximab scan. RESULTS: Among 44 complete responses, PET-avid 89Zr-girentuximab results were associated with significant changes in stated management preferences across all 9 vignettes (100%). Absolute change in "likely" responses ranged from 9.1% to 56.8% (P < .05). PET-avid results pertaining to localized renal masses led to absolute decreases in responses favoring biopsy ranging from 38.6% to 56.8% (P < .0001). For locally advanced or recurrent cases, PET-avid findings led to absolute changes in response distribution ranging from 9.1% to 36.4% (P = .003 to P < .0001). Non-PET-avid results significantly influenced hypothetical management in 7 of 9 vignettes (78%). CONCLUSIONS: PET-avid 89Zr-girentuximab results significantly influenced hypothetical decision-making in a variety of ccRCC scenarios. Most notably, PET-avid results reduced rates of responses favoring biopsy. Non-PET-avid results impacted response distribution in a majority of vignettes but often shifted management toward additional diagnostic work-up. These results highlight the need for future exploration of the application of the 89Zr-girentuximab PET/CT in clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- [89Zr]Zr-girentuximab PET/CT in indeterminate renal masses and advanced clear cell renal cell carcinoma: clinical utility and management impact in a real-world cohort.European journal of nuclear medicine and molecular imaging · 2026
- Cost-Effectiveness of Incorporating [⁸⁹ Zr]Zr-Girentuximab Positron Emission Tomography–Computed Tomography for Characterizing Small Renal MassesThe Journal of Urology · 2026
- Diagnostic Performance of [68Ga]Ga-DPI-4452 PET/CT in Patients with Clear Cell Renal Cell Carcinoma: A Prospective Trial.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
- CAIX-targeted PET/CT in clear cell renal cell carcinoma: a systematic review of current evidence and clinical perspectives.Minerva urology and nephrology · 2026
- From Metabolism to Molecular Phenotype: Carbonic Anhydrase IX-Targeted [68Ga]Ga-DPI-4452 PET/CT in Renal Cell Carcinoma: A Prospective Multicenter Comparison with [18F]FDG PET/CT.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
- Diagnostic accuracy of carbonic anhydrase IX-targeted PET/CT for detection of clear cell renal cell carcinoma in patients with renal masses: a systematic review and meta-analysis of diagnostic test accuracy studies.Nuclear medicine communications · 2026