Journal of chromatography. A

Quinoline bridging chlorine-functionalized covalent organic framework for solid-phase microextraction of trace organochlorine pesticides in environmental water.

Hongyan Zeng, Huan Cai, Jingpu Tang, Hong Yang, Chenchen Lin, Xiaoping Wu

Key Laboratory for Analytical Science of Food Safety and Biology, College of Chemistry, Fuzhou University, Fuzhou, 350116, China; International (Hong Kong, Macao and Taiwan) Joint Laboratory on food safety and environmental analysis, Fuzhou University, Fuzhou, 350116, China. · College of Chemical Engineering, Fuzhou University, Fuzhou, 350116, China; Engineering Technology Research Center on Reagent and Instrument for Rapid Detection of Product Quality and Food Safety, Fuzhou 350116, China.

Key points

From the paper's conclusion
  • These results demonstrate that the QCl-COF effectively reconciles enrichment performance and stability, serving as a durable SPME coating for trace OCP analysis in environmental waters.

Abstract

Achieving a compromise between adsorption performance and stability remains a critical challenge in the fabrication of functionalized adsorbent materials. In this work, a quinoline bridging chlorine-functionalized covalent organic framework (QCl-COF) was successfully synthesized and employed for the efficient solid-phase microextraction (SPME) enrichment of trace organochlorine pesticides (OCPs) in environmental water samples. The as-prepared QCl-COF exhibited a large specific surface area and excellent thermal and chemical stability. X-ray photoelectron spectroscopy (XPS) analysis indicated that halogen bonding and π-π interactions form between the QCl-COF coating and OCPs, together with the hydrophobicity and large specific surface area of QCl-COF, providing multiple synergistic interactions for the recognition of OCPs. Benefiting from these interactions, the QCl-COF-coated SPME fiber demonstrated exceptional enrichment performance toward OCPs, with enrichment factors ranging from 888 to 4212. Under optimal conditions, the QCl-COF-based SPME was successfully coupled with gas chromatography-mass spectrometry (GC-MS) and exhibited a broad linear range (0.1-1000 ng L-1), low limits of detection (0.011-0.39 ng L-1), and satisfactory recoveries (78.5 %-119.0 %) for ten OCPs. These results demonstrate that the QCl-COF effectively reconciles enrichment performance and stability, serving as a durable SPME coating for trace OCP analysis in environmental waters.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers