Fabrication of magnetic zeolitic imidazolate framework‑8/sulfonated covalent organic framework composites for high-sensitivity detection of trace fluoroquinolone residues in aquatic products.
Zhikun Li, Fuqiang Sun, Wei Zhang, Ziping Huo, Ming Su, Shu-Xuan Liang
Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, Baoding 071002, China. · Baoding Center for Disease Control and Prevention, Baoding 071000, China.
Key points
From the paper's conclusion- The Fe₃O₄/ZIF-8/TpPa-SO₃H composite combines magnetic responsiveness, a microporous framework, and sulfonate-mediated electrostatic and hydrogen-bonding interactions.
Abstract
Fluoroquinolone (FQ) residues in aquatic products pose serious food safety and antimicrobial resistance concerns. Existing analytical methods often suffer from laborious sample pretreatment or insufficient sensitivity. A ternary magnetic composite Fe₃O₄/ZIF-8/TpPa-SO₃H was designed to achieve rapid, selective, and recyclable enrichment of three representative fluoroquinolones, namely enoxacin (ENO), norfloxacin (NOR), and ciprofloxacin (CIP) prior to HPLC-fluorescence detection (FLD). Adsorption kinetics were better described by the pseudo-second-order model (R² > 0.99), while the Langmuir model provided a better fit to the adsorption isotherms, with maximum capacities reaching 336.05 mg/g at 318 K. Complementary spectroscopic and theoretical analyses suggested that electrostatic interactions, hydrogen bonding, π-π interactions, and possible coordination contributed to FQ adsorption. Under optimized MSPE conditions (6.0 mg adsorbent, 25 min adsorption at pH 6, 3 mL of 5% NH₃ in methanol as eluent), the method achieved limits of detection (LOD) of 1.28-1.34 µg/kg and limits of quantification (LOQ) of 4.01-4.32 µg/kg. Linear ranges spanned 5-1000 µg/kg (r > 0.99). Intra-day and inter-day relative standard deviations were 3.8-5.6% and 4.1-8.4%, respectively. Spike recoveries individually evaluated across nine fish and shrimp species ranged from 85.3% to 105.3%, with matrix effects between 88.9% and 108.4%. The adsorbent retained >90% extraction efficiency after eight reuse cycles. The Fe₃O₄/ZIF-8/TpPa-SO₃H composite combines magnetic responsiveness, a microporous framework, and sulfonate-mediated electrostatic and hydrogen-bonding interactions. The developed MSPE-HPLC-FLD method provides a reliable analytical approach for monitoring fluoroquinolone residues in complex seafood matrices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fabrication of Fluorinated Magnetic Covalent Organic Frameworks for the Extraction of Fluoroquinolone Residues Coupled with HPLC DetectionMolecules · 2026
- Technological advancements and challenges in the analysis of fluoroquinolone antibiotic environmental residues.Talanta · 2026
- Enrichment of five fluoroquinolones from milk, pork and chicken samples with cyano-functionalized cationic porous polymer.Food chemistry · 2026
- Selective adsorption of fluoroquinolones by a chemically modified β-cyclodextrin composite: Combined contributions of hydrophobic cavity and functional groups.Environmental research · 2026
- Determination of Fluoroquinolones and Tetracyclines in Natural Waters by Capillary Electrophoresis with UV Detection in Combination with Preliminary Solid-Phase Microextraction with Polydopamine-Coated Fe3O4 NanoparticlesJournal of Analytical Chemistry · 2026
- Magnetic Trinity Platform Based on Renewable Humic Acid for Closed-Loop Management of Antibiotics via Adsorption-Detection-Catalytic Degradation SynergyACS Sustainable Chemistry & Engineering · 2026