Journal of chromatography. A

Fabrication of magnetic zeolitic imidazolate framework‑8/sulfonated covalent organic framework composites for high-sensitivity detection of trace fluoroquinolone residues in aquatic products.

Zhikun Li, Fuqiang Sun, Wei Zhang, Ziping Huo, Ming Su, Shu-Xuan Liang

Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, Baoding 071002, China. · Baoding Center for Disease Control and Prevention, Baoding 071000, China.

Key points

From the paper's conclusion
  • The Fe₃O₄/ZIF-8/TpPa-SO₃H composite combines magnetic responsiveness, a microporous framework, and sulfonate-mediated electrostatic and hydrogen-bonding interactions.

Abstract

Fluoroquinolone (FQ) residues in aquatic products pose serious food safety and antimicrobial resistance concerns. Existing analytical methods often suffer from laborious sample pretreatment or insufficient sensitivity. A ternary magnetic composite Fe₃O₄/ZIF-8/TpPa-SO₃H was designed to achieve rapid, selective, and recyclable enrichment of three representative fluoroquinolones, namely enoxacin (ENO), norfloxacin (NOR), and ciprofloxacin (CIP) prior to HPLC-fluorescence detection (FLD). Adsorption kinetics were better described by the pseudo-second-order model (R² > 0.99), while the Langmuir model provided a better fit to the adsorption isotherms, with maximum capacities reaching 336.05 mg/g at 318 K. Complementary spectroscopic and theoretical analyses suggested that electrostatic interactions, hydrogen bonding, π-π interactions, and possible coordination contributed to FQ adsorption. Under optimized MSPE conditions (6.0 mg adsorbent, 25 min adsorption at pH 6, 3 mL of 5% NH₃ in methanol as eluent), the method achieved limits of detection (LOD) of 1.28-1.34 µg/kg and limits of quantification (LOQ) of 4.01-4.32 µg/kg. Linear ranges spanned 5-1000 µg/kg (r > 0.99). Intra-day and inter-day relative standard deviations were 3.8-5.6% and 4.1-8.4%, respectively. Spike recoveries individually evaluated across nine fish and shrimp species ranged from 85.3% to 105.3%, with matrix effects between 88.9% and 108.4%. The adsorbent retained >90% extraction efficiency after eight reuse cycles. The Fe₃O₄/ZIF-8/TpPa-SO₃H composite combines magnetic responsiveness, a microporous framework, and sulfonate-mediated electrostatic and hydrogen-bonding interactions. The developed MSPE-HPLC-FLD method provides a reliable analytical approach for monitoring fluoroquinolone residues in complex seafood matrices.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers