Journal of chromatography. A

Poly(styrene-maleic anhydride)@γ-cyclodextrin-MOFs as chiral stationary phase for capillary electrochromatography.

Yan Zhang, Xi Chu, Rongtang Wang, Jinglin Wang, Rongyue Zhang, Juan Qiao

School of Biomedicine and Health Science, Beijing Institute of Petrochemical Technology, Beijing, 102617, China. · School of Biomedicine and Health Science, Beijing Institute of Petrochemical Technology, Beijing, 102617, China. Electronic address: qiaojuan@bipt.edu.cn.

Key points

From the paper's conclusion
  • Inspired by host-guest interactions and polymer-assisted immobilization, a novel capillary electrochromatography (CEC) system was constructed in this study, using polystyrene-maleic anhydride@γ-cyclodextrin metal-organic frameworks (PSM@γ-CD-MOFs) as the chiral stationary phase (CSP), to achieve efficient separation of dansyl-labeled D,L-amino acids (Dns-D,L-AAs).

Abstract

Efficient enantiomeric separation of amino acids is critical for drug research and development (R&D) and biomedical analysis. However, the resolution of traditional chiral selectors is often constrained by insufficient stability and a limited number of recognition sites. Inspired by host-guest interactions and polymer-assisted immobilization, a novel capillary electrochromatography (CEC) system was constructed in this study, using polystyrene-maleic anhydride@γ-cyclodextrin metal-organic frameworks (PSM@γ-CD-MOFs) as the chiral stationary phase (CSP), to achieve efficient separation of dansyl-labeled D,L-amino acids (Dns-D,L-AAs). The directional immobilization of γ-CD within the MOFs skeleton endows the CSP with highly ordered and efficient chiral recognition capabilities, converting originally randomly distributed interaction sites into a synergistic and high-efficiency separation system, thereby significantly improving resolution. Through systematic optimization of polymer ratio, coating concentration, buffer pH, and electric field parameters, the maximum resolution (Rs) reached 2.0, which is a substantial enhancement compared with that of traditional cyclodextrin-based systems. Baseline separation of multiple pairs of Dns-D,L-AA enantiomers was achieved in a pure aqueous system. This method exhibited excellent performance in terms of linear range, sensitivity, and quantitative repeatability, and was successfully applied to measurement of D,L-leucine concentration-time profiles in rat serum, demonstrating its applicability to monitoring amino acid enantiomers in serum. This work explores the use of polymer-MOFs coatings in chiral analysis and their potential biomedical applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers