Journal of chromatography. A

One-pot synthesis of an amphoteric polydopamine-silica sorbent for solid-phase extraction of pharmaceuticals from water and urine.

Laila Alshatti, Mohamed Rashad, Abdullah Alhendal

The Public Authority for Applied Education and Training College of Nursing, General Science Department, State of Kuwait, P.O. Box 64923, 70466, Shuwaikh-B, Kuwait. Electronic address: La.alshatti@paaet.edu.kw. · Department of Chemistry, College of Science, Kuwait University, Sabah Al Salem University City, P.O. Box 5969, Safat 13060, Shadadiya, Kuwait.

Key points

From the paper's conclusion
  • Validated in spiked tap water (92-98 %, RSD < 5%) and synthetic urine (89-97 %, RSD < 5 %), the method demonstrated robust anti-matrix interference capability.

Abstract

A polydopamine-silica (PDA-SiO2) hybrid sorbent was fabricated via a one-pot, base-catalyzed sol-gel condensation and oxidative polymerization strategy, employing dodecyltrimethylammonium bromide (DTAB) as a cationic surface texture-directing agent. Following thorough sequential washing to ensure complete DTAB removal, the final sorbent - comprising an APTES-grafted silica core (providing protonatable amine binding sites) enveloped by a conformal polydopamine shell (5-10 nm, offering π-π stacking, cation-π, and hydrogen bonding interaction pathways)-was systematically evaluated for the simultaneous preconcentration of acidic (naproxen, mefenamic acid) and basic (amitriptyline, tamoxifen) pharmaceuticals from tap water and simulated biological matrices. Material characterization by SEM, TEM, FT-IR, XPS, BET, and zeta potential confirmed a non-porous, solid-core architecture with an amphoteric surface charge profile (pHpzc = 5.98), which is substantially higher than that of unmodified silica (pHpzc ≈ 2-3), confirming successful APTES and PDA functionalization. Under optimized conditions (pH 7.0, 5.0% (w/v) NaCl, 10.0 mL sample volume), simultaneous quantitative retention of all four analytes was achieved. A pH-responsive sequential elution protocol - 0.1% formic acid in methanol for basic drugs, followed by 2% NH4OH in methanol for acidic drugs - delivered class-selective desorption with recoveries of 89-98% across both tap water and synthetic urine matrices. The method exhibited excellent linearity over 1.0-500 µg L-1 (R2 ≥ 0.9982), limits of detection of 0.1-0.3 µg L-1, and a theoretical enrichment factor of 20 (10.0 mL → 0.5 mL), with experimentally confirmed values of 18.2-19.6 across all analytes, and maintained quantitative performance (recovery >91%) over five of six consecutive extraction-regeneration cycles, with a marginal decline to 86-88% observed only in the sixth cycle. Validated in spiked tap water (92-98 %, RSD < 5%) and synthetic urine (89-97 %, RSD < 5 %), the method demonstrated robust anti-matrix interference capability.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers