The challenge of identification in the analysis of per- and polyfluoroalkyl substances in food: risks of false positive by liquid chromatography tandem mass spectrometry.
Xanthippe Theurillat, Bjorn Eriksen, Thierry Delatour
Société des Produits Nestlé SA. - Nestlé Research Lausanne, Vers-chez-les-Blanc, 1000 Lausanne 26, Switzerland. Electronic address: xanthippi.theurillat@rdls.nestle.com. · Société des Produits Nestlé SA. - Nestlé Research Lausanne, Vers-chez-les-Blanc, 1000 Lausanne 26, Switzerland. Electronic address: bjorn.eriksen@rdls.nestle.com.
Key points
From the paper's conclusion- Reliable identification of per- and polyfluoroalkyl substances (PFAS) in complex food matrices remains analytically challenging, particularly for compounds exhibiting limited fragmentation in low-resolution mass spectrometry.
Abstract
Reliable identification of per- and polyfluoroalkyl substances (PFAS) in complex food matrices remains analytically challenging, particularly for compounds exhibiting limited fragmentation in low-resolution mass spectrometry. Current identification criteria require at least two ion transitions; however, for short-chain PFAS, the second transition is often a precursor→precursor signal or a non-specific fragment, which may not provide structural confirmation. In this study, the risk of false positive identification is demonstrated using two case studies. First, apparent detection of perfluoropentanoic acid (PFPeA) in soluble coffee was shown to be an analytical artefact after modification of chromatographic conditions revealed a co-eluting interference. Second, analysis of N-methyl perfluorooctane sulfonamidoethanol (N-MeFOSE) in pizza samples demonstrated that transitions based on ammonium acetate adducts and non-specific fragments (m/z 59) do not provide confirmation. In both cases, alternative approaches (LC-MS/MS alternative chromatographic conditions and GC-MS/MS) demonstrated the absence of the target analytes. These findings highlight that in cases where only a single or non-selective MRM transition is available, the use of an alternative analytical approach such as GC-MS/MS, LC-MS/MS with modified chromatographic conditions, or LCHRMS should be considered to ensure reliable confirmation. Verification through spiking experiments may reveal the presence of co-eluting matrix interferences, and a critical evaluation of suspect results prior to reporting is essential to prevent misidentification of PFAS and the generation of false positive results.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improved Non-Targeted Coverage of Per- and Polyfluoroalkyl Substances (PFAS) Using Mass Defect-Informed Data-Dependent AnalysisAnalytical Chemistry · 2026
- LC–MS/MS method for per- and polyfluoroalkyl substances (PFAS) analysis in food products, First Action 2025.10Journal of AOAC International · 2026
- Advanced Mass Spectrometric Strategies for Per- and Polyfluoroalkyl Substances Characterization: Current Limitations and Future Directions.Mass spectrometry reviews · 2026
- Enhanced selectivity for PFAS analysis in complex biological matrices by LC-MS/MS: Application to mouse feces and liver.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026
- Non-targeted screening of per- and polyfluoroalkyl substances: Advanced methods, challenges, and environmental healthEco-Environment & Health · 2026
- From Sampling to Screening: A Review of Targeted and Non-Targeted PFAS Analysis in Environmental SamplesCritical Reviews in Analytical Chemistry · 2026