Journal of chromatography. A

The challenge of identification in the analysis of per- and polyfluoroalkyl substances in food: risks of false positive by liquid chromatography tandem mass spectrometry.

Xanthippe Theurillat, Bjorn Eriksen, Thierry Delatour

Société des Produits Nestlé SA. - Nestlé Research Lausanne, Vers-chez-les-Blanc, 1000 Lausanne 26, Switzerland. Electronic address: xanthippi.theurillat@rdls.nestle.com. · Société des Produits Nestlé SA. - Nestlé Research Lausanne, Vers-chez-les-Blanc, 1000 Lausanne 26, Switzerland. Electronic address: bjorn.eriksen@rdls.nestle.com.

Key points

From the paper's conclusion
  • Reliable identification of per- and polyfluoroalkyl substances (PFAS) in complex food matrices remains analytically challenging, particularly for compounds exhibiting limited fragmentation in low-resolution mass spectrometry.

Abstract

Reliable identification of per- and polyfluoroalkyl substances (PFAS) in complex food matrices remains analytically challenging, particularly for compounds exhibiting limited fragmentation in low-resolution mass spectrometry. Current identification criteria require at least two ion transitions; however, for short-chain PFAS, the second transition is often a precursor→precursor signal or a non-specific fragment, which may not provide structural confirmation. In this study, the risk of false positive identification is demonstrated using two case studies. First, apparent detection of perfluoropentanoic acid (PFPeA) in soluble coffee was shown to be an analytical artefact after modification of chromatographic conditions revealed a co-eluting interference. Second, analysis of N-methyl perfluorooctane sulfonamidoethanol (N-MeFOSE) in pizza samples demonstrated that transitions based on ammonium acetate adducts and non-specific fragments (m/z 59) do not provide confirmation. In both cases, alternative approaches (LC-MS/MS alternative chromatographic conditions and GC-MS/MS) demonstrated the absence of the target analytes. These findings highlight that in cases where only a single or non-selective MRM transition is available, the use of an alternative analytical approach such as GC-MS/MS, LC-MS/MS with modified chromatographic conditions, or LCHRMS should be considered to ensure reliable confirmation. Verification through spiking experiments may reveal the presence of co-eluting matrix interferences, and a critical evaluation of suspect results prior to reporting is essential to prevent misidentification of PFAS and the generation of false positive results.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers