Journal of chromatography. A

Fast HPLC separation of rare earths with direct VUV detection and superficially porous particle-based stationary phases.

Reza Salehi, Maria Olds, Saba Aslani, Annika Dombrowski, Daniel W Armstrong

The University of Texas at Arlington, Chemistry Department, 700 Planetarium Place, CPB110, Arlington, TX, 76019, USA. · VUV Analytics, 1500 Arrow Point Drive, Suite 805, Building 8, Cedar Park, TX, 78613, USA.

Key points

From the paper's conclusion
  • A liquid chromatography-vacuum ultraviolet detection (LC-VUV) method was developed for isocratic rare-earth element separation and direct detection using aqueous mobile phases containing α-hydroxyisobutyric acid (HIBA) and γ-aminopropylsilane-halodecane silica stationary phases.

Abstract

A liquid chromatography-vacuum ultraviolet detection (LC-VUV) method was developed for isocratic rare-earth element separation and direct detection using aqueous mobile phases containing α-hydroxyisobutyric acid (HIBA) and γ-aminopropylsilane-halodecane silica stationary phases. Chlorodecane- and iododecane-modified fully porous and superficially porous γ-APS columns were evaluated to determine how stationary-phase chemistry, stationary-phase format, HIBA concentration, and pH affect retention. Retention studies and HIBA-free control injections support a coupled mechanism in which Ln-HIBA species interact with the modified stationary phase, rather than simple retention of free HIBA or uncomplexed hydrated Ln(III) ions. Iododecane phases produced stronger retention, especially for heavier lanthanides, while SPP columns provided faster separations. LC-VUV enabled direct detection of La-Lu, excluding Pm, under isocratic aqueous HIBA conditions. Cl-SPP stationary phase separated most lanthanides in <4 min, while I-SPP expanded the retention window for middle and heavy lanthanides in <10 min. Dy/Y remained the main unresolved pair. VUV provided measurable LODs for all evaluated REEs, including Sc, Y, La, Gd, Tb, Yb, and Lu, which were not detected by UV-Vis under the tested conditions. The lowest VUV LODs ranged from 0.6 ppm for Ce to 29 ppm for Lu. VUV spectra provided complementary information for selected elements and matrix components, and a real Nd-Fe-B magnet digest demonstrated baseline separation of Fe and Nd.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Fast HPLC separation of rare earths with direct VUV detection and superficially porous particle-based stationary phases — Science Skim