Journal of chromatography. A

Syringe filter-SPE for determination of organophosphorus pesticides and atrazine in environmental water samples using Cr-MOF/ graphene nano-powder composite as sorbent.

Aveen Mustafa Mohammed, Ali Khodayari, Sorayya Ataei, Soleyman Moinfar

Department of Chemistry, College of Science, University of Duhok, Kurdistan Region, Iraq. · Department of Chemistry, Faculty of Science, University of Mohaghegh Ardabili, Ardabil, 56199-11367, Iran.

Key points

From the paper's conclusion
  • The findings indicated that the Cr-MOF/GNP nanocomposite exhibited enhanced adsorption efficacy and a reduced detection limit for all nine target pesticides compared with unmodified NH2-MIL-101 (Cr).

Abstract

The efficiency of solid-phase extraction (SPE) for determining low-concentration organophosphorus pesticides and atrazine in real samples depends on the adsorbent's ability to adsorb the analyte before entering the chromatography system. MOFs can be an excellent option as adsorbents for extracting analytes because of their large specific surface area and high adsorption capacity, particularly NH2-MIL-101(Cr). The aim of this study is to enhance extraction efficiency and sensitivity in a syringe-filter solid-phase extraction (SPE) method using a novel NH2-MIL-101(Cr) composite for the extraction of several organophosphorus pesticides (OPPs) and atrazine from environmental water samples. In this study, an NH2-MIL-101(Cr)/graphene nanocomposite was synthesized for the first time and packed into a syringe filter as an adsorbent, thereby increasing the method's sensitivity. Various characterisation techniques, including fourier-transform infrared spectroscopy (FTIR), Brunauer-Emmett-Teller (BET), thermogravimetric analysis (TGA), X-ray diffraction (XRD), and scanning electron microscopy (SEM) were employed to verify the successful production of the nanocomposite. The variables influencing the extraction efficiency of NH2-MIL-101(Cr)/Graphene nano-powder-syringe filter-SPE/GC-MS, including sample volume, pH, elution solvent volume, and elution solvent type, were optimized. The findings indicated that the Cr-MOF/GNP nanocomposite exhibited enhanced adsorption efficacy and a reduced detection limit for all nine target pesticides compared with unmodified NH2-MIL-101 (Cr). The technique demonstrated a linear response range of 1.0 to 300.0 μg/L and achieved detection limits of 0.2 to 6.0 μg/L. The results demonstrated significant reproducibility, with outstanding recovery rates ranging from 83.0% to 103.0% across increasing concentrations from 15.0 to 60.0 μg/L and relative standard deviation values ranging from 3.2% to 6.3%.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers