Retention behavior of 39 cannabinoids in reverse-phase liquid chromatography using C18 or phenyl hexyl columns.
Walter B Wilson
Chemical Sciences Division, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD, 20899, USA. Electronic address: walter.wilson@nist.gov.
Key points
From the paper's conclusion- This study evaluates trends in cannabinoid retention for Δ9-THC, its isomers, and analogs on both column types.
Abstract
Reverse-phase liquid chromatography with ultraviolet detection (LC-UV) is the primary analytical technique for quantifying Δ9-THC in Cannabis plant materials since the passage of the Agriculture Improvement Act of 2018. This legislation established a Δ9-THC threshold of 0.3 % (by "dry weight") to distinguish hemp from marijuana, effectively removing hemp from the United States Drug Enforcement Administration's list of controlled substances. In 2022, the Chemical Sciences Division (CSD) at the National Institute of Standards and Technology (NIST) demonstrated accurate and precise analytical measurements of Δ9-THC, Δ8-THC, and nine other cannabinoids in Cannabis plant and oil samples using LC-UV absorbance detection. This method used a C18 column to resolve cannabinoids using an ACN/H2O mobile phase. Recently, the commercial landscape has shifted as manufacturers utilize synthetic processes to convert cannabidiol (CBD) from hemp extracts into finished products containing various isomers or analogs of Δ9-THC. This practice has introduced chromatographic interferences from synthetic by-products, which can compromise the accuracy of Δ9-THC measurements. In response, NIST CSD has modified the original LC-UV method to develop two refined methods designed to minimize these interferences. The LC-UV screening method currently employed by NIST CSD was evaluated for its ability to resolve 39 cannabinoids and compared with a novel LC-UV method using a Phenyl Hexyl (pH) column. This study evaluates trends in cannabinoid retention for Δ9-THC, its isomers, and analogs on both column types. While both stationary phases exhibited predictable retention trends for THC homologs based on alkyl side-chain length, the pH column provided a unique correlation between THC isomer elution and the specific position of the double bond within the cyclohexene ring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a quantitative LC-MS/MS method for the analysis of seventeen cannabinoids in various ingestible cannabinoid hemp products.Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment · 2026
- HPLC-UV quantitation of synthetically derived THC, THCP, and HHC isomers in commercial vaping liquids and edibles (2019-2024).Journal of forensic sciences · 2026
- Method Development for a Sensitive and Reliable Quantification of 39 Total Cannabinoids and Their Metabolites by UPLC-MS/MS.Toxics · 2026
- Declared vs determined: Analysis of cannabinoids in commercially available products on the Maltese marketPhytochemistry Letters · 2026
- Non-psychotropic phytocannabinoids, Δ9-THC and their metabolites by means of volumetric dried blood microsamplingJournal of Cannabis Research · 2026
- HPLC–DAD method for cannabinoid quantification in Brazilian Cannabis oils and extractsJournal of Cannabis Research · 2026